Final Text
CHAPTER 880
GENERAL [ VPDES ] PERMIT FOR DISCHARGES OF STORMWATER FROM
CONSTRUCTION ACTIVITIES
9VAC25-880-1. Definitions.
The words and terms used in this chapter shall have the meanings defined in the Virginia Stormwater Management Act (Article 2.3 (§ 62.1-44.15:24 et seq.) of Chapter 3.1 of Title 62.1 of the Code of Virginia), this chapter, and 9VAC25-870 unless the context clearly indicates otherwise, except as otherwise specified in this section. Terms not defined in the Act, this chapter, or 9VAC25-870 shall have the meaning attributed to them in the federal Clean Water Act (33 USC § 1251 et seq.) (CWA). For the purposes of this chapter:
[ "Business day" means Monday through Friday excluding state holidays. ]
"Commencement of [ construction land
disturbance ]" means the initial disturbance of soils associated with
clearing, grading, or excavating activities or other construction activities
(e.g., stockpiling of fill material).
[ "Construction site" means the land where any land-disturbing activity is physically located or conducted, including any adjacent land used or preserved in connection with the land-disturbing activity. ]
"Final stabilization" means that one of the following situations has occurred:
1. All soil disturbing activities at the site have been completed and a permanent vegetative cover has been established on denuded areas not otherwise permanently stabilized. Permanent vegetation shall not be considered established until a ground cover is achieved that is uniform (e.g., evenly distributed), mature enough to survive, and will inhibit erosion.
2. For individual lots in residential construction, final stabilization can occur by either:
a. The homebuilder completing final stabilization as specified in subdivision 1 of this definition; or
b. The homebuilder establishing temporary [ soil ] stabilization, including perimeter controls for an individual lot prior to occupation of the home by the homeowner, and informing the homeowner of the need for, and benefits of, final stabilization.
3. For construction projects on land used for agricultural purposes
[ (e.g., pipelines across crop or range land) ], final
stabilization may be accomplished by returning the disturbed land to its
preconstruction agricultural use. Areas disturbed that were not previously used
for agricultural activities, such as buffer strips immediately adjacent to
surface waters, and areas that are not being returned to their preconstruction
agricultural use must meet the final stabilization criteria specified in
subdivision 1 or 2 of this definition.
"Minimize" means to prevent, reduce, or eliminate
using practicable control measures to meet the conditions of this state permit.
"Immediately" means as soon as practicable, but
no later than the end of the next [ work business ]
day, following the day when the [ earth-disturbing
land-disturbing ] activities have temporarily or permanently
ceased. In the context of this [ general ] permit,
"immediately" is used to define the deadline for initiating
stabilization measures.
"Impaired waters" means surface waters identified as impaired on the 2012 § 305(b)/303(d) Water Quality Assessment Integrated Report.
[ "Infeasible" means not technologically possible or not economically practicable and achievable in light of best industry practices. ]
"Initiation of stabilization activities" means:
1. Prepping the soil for vegetative or nonvegetative stabilization;
2. Applying mulch or other nonvegetative product to the exposed area;
3. Seeding or planting the exposed area;
4. Starting any of the above activities on a portion of the area to be stabilized, but not on the entire area; or
5. Finalizing arrangements to have the stabilization product fully installed in compliance with the applicable deadline for completing stabilization.
This list [ of examples ] is
not exhaustive.
"Measurable storm event" means a rainfall event producing 0.25 inches of rain or greater over 24 hours.
[ "Stabilized" means land that has been treated to withstand normal exposure to natural forces without incurring erosion damage. ]
9VAC25-880-10. Purpose.
This general permit regulation [ authorizes governs ]
stormwater discharges from regulated construction activities. For the purposes
of this chapter, these discharges are defined as stormwater discharges associated
with large construction activity, and stormwater discharges associated with
small construction activity. [ Stormwater discharges associated with other
types of industrial activity shall not have coverage under this general
permit. ] This general permit covers only discharges through a point
source to state surface waters or through a municipal or
nonmunicipal separate storm sewer system to state surface waters.
Stormwater discharges associated with industrial activity that originate from the
site after construction activities that have been completed and the
site has undergone final stabilization are not authorized by this [ state
general ] permit. The goal of this state permit is to minimize
the discharge of stormwater pollutants from construction activity by requiring
that the operator plan and implement appropriate control measures.
[ 9VAC25-880-15. Applicability of incorporated references based on the dates that they became effective.
Except as noted, when a regulation of the United States set
forth in the Code of Federal Regulations is referenced and incorporated herein,
that regulation shall be as it exists and has been published in the July 1, 2009
2013, update. ]
9VAC25-880-20. Effective date of [ general ] permit.
This general permit is effective on July 1, 2009 2014.
The general permit will expire on June 30, 2014 2019. This
general permit is effective for any covered operator upon compliance with all provisions
of [ 4VAC50-60-1130 9VAC25-880-30. ]
9VAC25-880-30. Authorization to discharge.
A. Any operator [ governed covered ]
by this general permit is authorized to discharge to state [ stormwater
associated with construction activities including stormwater associated with emergency-related
construction related activities ] to surface waters of the
Commonwealth of Virginia in accordance with 9VAC25-880-50 A 4 [ provided
that the operator ] has filed [ submits a
complete and accurate registration statement in accordance with 9VAC25-880-50 and
receives acceptance of the registration statement by the board, ] submitted
[ submits any fees required by Part XIII of 9VAC25-870
(9VAC25-870-700 et seq.) unless exempted pursuant to 9VAC25-880-50 A 3 (a) ],
complied with the requirements of 9VAC25-880-50, complies with the requirements
of 9VAC25-880-80 through 9VAC25-880-90 [ , and complies with the
requirements of 9VAC25-880-70 and ] provided that:
[ 1. Prior to commencing ] construction
[ land disturbing activities, the operator ] shall
obtain approval of an erosion and sediment control plan from the VESCP
authority in the locality in which the construction activity is to occur unless
the operator receives from the VESCP authority an "agreement in lieu of a
plan" as defined in 9VAC25-840-10, or is exempt from the requirement to
submit an erosion and sediment control plan by the Erosion and Sediment Control
Law and Erosion and Sediment Control Regulations (9VAC25-840); [ obtains
approval of:
a. An erosion and sediment control plan from the
appropriate VESCP authority as authorized under the Virginia Erosion and
Sediment Control Regulations, 9VAC25-840, unless the operator receives from the
VESCP an "agreement in lieu of a plan" as defined in 9VAC25-840-10 or
prepares the erosion and sediment control plan in accordance with annual
standards and specifications approved by the board. The operator of any
land-disturbing activity that is not required to obtain erosion and sediment
control plan approval from a VESCP authority or is not required to adopt
department-approved annual standards and specifications shall submit the
erosion and sediment control plan to the department for review and approval
prior to land disturbance; and
b. A stormwater management plan from the appropriate
VSMP authority as authorized under the Virginia Stormwater Management Program
Regulations, 9VAC25-870. The operator of any land-disturbing activity that is
not required to obtain stormwater management plan approval from a VSMP
authority or is not required to adopt department-approved annual standards and
specifications shall submit the stormwater management plan to the department
for review and approval prior to land disturbance.
Emergency related construction activities are not
required to obtain the approvals specified in subdivisions 1 a and b of this
subsection prior to the commencement of land disturbance.
2. ] The stormwater discharge [ Discharges
authorized by this state permit may be ] combined [ commingled
with other sources of stormwater that are not required to be covered under a
state permit, so long as the ] combined [ commingled
discharge is in compliance with this state permit. ] Any discharge
[ Discharges authorized by a ] different [ separate
state or a VPDES permit may be commingled with discharges authorized by this
state permit so long as all such discharges comply with all applicable state ]
permits [ permit requirements; ]
[ 3. Discharges to impaired waters ] for
which a "total maximum daily load" (TMDL) wasteload allocation has
been established [ , including discharges to surface waters
located within a TMDL watershed are not eligible for coverage under this
general permit unless ] they are otherwise authorized in accordance
with 9VAC25-880-70 Section II D 6 and [ the operator develops,
implements, and maintains a stormwater pollution prevention plan that minimizes
applicable observed sources identified in the 2012 §305(b)/303(d) Water Quality
Assessment Integrated Report, minimizes pollutants of concern identified in a
TMDL approved prior to July 1, 2014 and is consistent with the ] requirements
and assumptions [ assumptions and requirements of ]
the wasteload allocations in the TMDL [ , all applicable TMDL
wasteload allocations. This only applies when construction activities discharge
or are reasonable expected to discharge an applicable observed source
identified in the 2012 §305(b)/303(d) Water Quality Assessment Report or a
pollutant of concern identified in a TMDL approved prior to July 1, 2014.;
and ]
4. Discharges to waters that have been identified as
impaired in the 2008 § 305(b)/303(d) Water Quality Assessment Integrated Report
are not eligible for coverage under this general permit unless they are
otherwise authorized in accordance with 9VAC25-880-70 Section I H.
[ 4. Authorized nonstormwater discharges. The
following nonstormwater discharges are authorized by this permit:
a. Discharges from fire fighting activities;
b. Fire hydrant flushings;
c. Water used to wash vehicles where detergents have not
been used and the wash water has been treated;
d. Water used to control dust that has been filtered,
settled, or similarly treated prior to discharge;
e. Potable water source, including uncontaminated
waterline flushings;
f. Routine external building wash down that does not use
detergents, solvents, or other wash chemicals and that have been filtered,
settled, or similarly treated prior to discharge;
g. Pavement washwater where spills or leaks of toxic or
hazardous materials have not occurred (or where all spilled material has been
removed prior to washing); where detergents, solvents, or other wash chemicals
are not used; and where the washwater has been filtered, settled, or similarly
treated prior to discharge;
h. Uncontaminated air conditioning or compressor
condensate;
i. Uncontaminated groundwater or spring water;
j. Foundation or footing drains where flows are not
contaminated with process materials such as solvents;
k. Uncontaminated excavation dewatering, including
dewatering of trenches and excavations that have been filtered, settled, or
similarly treated prior to discharge; and
l. Landscape irrigation.
1. The operator submits a complete and accurate registration statement, if required to do so, in accordance with 9VAC25-880-50 and receives acceptance of the registration by the board;
2. The operator submits any permit fees, if required to do so, in accordance with 9VAC25-870-700 et seq.;
3. The operator complies with the applicable requirements of 9VAC25-880-70;
4. The operator obtains approval of:
a. An erosion and sediment control plan from the appropriate VESCP authority as authorized under the Erosion and Sediment Control Regulations (9VAC25-840), unless the operator receives from the VESCP an "agreement in lieu of a plan" as defined in 9VAC25-840-10 or prepares the erosion and sediment control plan in accordance with annual standards and specifications approved by the department. The operator of any land-disturbing activity that is not required to obtain erosion and sediment control plan approval from a VESCP authority or is not required to adopt department-approved annual standards and specifications shall submit the erosion and sediment control plan to the department for review and approval; and
b. A stormwater management plan from the appropriate VSMP authority as authorized under the Virginia Stormwater Management Program (VSMP) Regulation (9VAC25-870), unless the operator prepares the stormwater management plan in accordance with annual standards and specifications approved by the department. The operator of any land-disturbing activity that is not required to obtain stormwater management plan approval from a VSMP authority or is not required to adopt department-approved annual standards and specifications shall submit the stormwater management plan to the department for review and approval; and
5. The board has not notified the operator that the discharge is not eligible for coverage in accordance with subsection B of this section. ]
B. In addition to other prohibitions, the following discharges
are not eligible for coverage under this general permit The board will
notify an operator that the discharge is not eligible for coverage under this
general permit in the event of any of the following:
1. Discharges for which the operator has been The
operator is required to obtain an individual permit [ according to
in accordance with ] 9VAC25-870-410 B;
2. Discharges The operator is proposing discharges to
state surface waters specifically named in other board
regulations or policies that prohibit such discharges; and
3. Stormwater discharges that the department in consultation
with the State Water Control Board determines cause, may reasonably be expected
to cause, or contribute to a violation of water quality standards (9VAC25-260).
The [ discharges cause discharge causes ],
may reasonably be expected to cause, or [ contribute
contributes ] to a violation of water quality standards
(9VAC25-260) [ as determined in consultation with the State
Water Control Board ];
4. The [ discharges violate discharge
violates ] or would violate the antidegradation policy in the
[ Virginia ] Water Quality Standards (9VAC25-260-30)
[ as determined in consultation with the State Water Control Board ];
or
5. The [ discharges are discharge
is ] not consistent with the assumptions and requirements of
[ a an applicable ] TMDL approved prior to
[ July 1, 2014 the term of this general permit ].
C. This [ state general ] permit
[ may ] also be used to [ authorize authorizes ]
stormwater discharges from support activities (e.g., concrete or asphalt batch
plants, equipment staging yards, material storage areas, excavated material
disposal areas, borrow areas) located on-site or off-site provided that:
1. The support activity is directly related to a construction site
that is required to have state permit coverage for discharges of stormwater
associated with construction activity [ applying for state
permit coverage that is required to have general permit coverage for
discharges of stormwater from construction activities ];
2. The support activity is not a commercial operation serving
[ or does not, nor does it ] serve
multiple unrelated construction [ projects activities ]
by different operators [ , and does not operate beyond the completion
of the construction activity at the last construction project it supports ];
and
3. [ The support activity does not operate beyond the completion of the last construction activity it supports;
4. ] The support activity is identified in the
registration statement at the time of [ state general ]
permit coverage;
3. [ 4. 5. ] Appropriate
control measures [ that will be implemented to minimize pollutant
discharges from the support activity ] are identified in a stormwater
pollution prevention plan [ covering and implemented to address ]
the discharges from the support activity areas ].; and
[ 5. 6. ] All applicable,
state, federal, and local approvals are obtained for the support activity.
D. Support activities located off-site are not required to be
covered under this general permit. Discharges of stormwater from off-site
support activities may be authorized under another state or [ a ]
VPDES permit. Where stormwater discharges from off-site support activities are
not authorized under this general permit, the land area of the off-site support
activity need not be included in determining the total land disturbance acreage
of the construction activity seeking general permit coverage.
E. [ Discharges authorized by this general permit may be commingled with other sources of stormwater that are not required to be covered under a state permit, so long as the commingled discharge is in compliance with this general permit. Discharges authorized by a separate state or VPDES permit may be commingled with discharges authorized by this general permit so long as all such discharges comply with all applicable state and VPDES permit requirements.
F. Authorized nonstormwater discharges. The following nonstormwater discharges from construction activities are authorized by this general permit:
1. Discharges from firefighting activities;
2. Fire hydrant flushings;
3. Water used to wash vehicles or equipment where soaps, solvents, or detergents have not been used and the wash water has been filtered, settled, or similarly treated prior to discharge;
4. Water used to control dust that has been filtered, settled, or similarly treated prior to discharge;
5. Potable water source, including uncontaminated waterline flushings;
6. Routine external building wash down where soaps, solvents, or detergents have not been used and the wash water has been filtered, settled, or similarly treated prior to discharge;
7. Pavement wash water where spills or leaks of toxic or hazardous materials have not occurred (or where all spilled or leaked material has been removed prior to washing); where soaps, solvents, or detergents have not been used; and where the wash water has been filtered, settled, or similarly treated prior to discharge;
8. Uncontaminated air conditioning or compressor condensate;
9. Uncontaminated groundwater or spring water;
10. Foundation or footing drains where flows are not contaminated with process materials such as solvents;
11. Uncontaminated, excavation dewatering, including dewatering of trenches and excavations that have been filtered, settled, or similarly treated prior to discharge; and
12. Landscape irrigations.
G. ] Receipt of Approval for coverage
under this general permit does not relieve any operator of the
responsibility to comply with any other applicable federal, state or local
statute, ordinance or regulation.
F. The department may allow exceptions to technical
criteria contained in the state permit in accordance with Part III of
9VAC25-870 (9VAC25-870-100 et seq.).
[ F. H. ] Continuation of
[ general ] permit coverage.
[ 1. ] Any operator that was authorized to
discharge under the general permit issued in 2009 [ under
9VAC25-880-70 Section III M ] and that submits a complete
[ and accurate ] registration statement [ that
is stamped as received by the department or postmarked 90 days prior to the
effective date of this general permit on or before June 30, 2014, ]
is authorized to continue to discharge under the terms of the 2009 general
permit until such time as the board either:
[ 1. a. ] Issues coverage to
the operator under this general permit or
[ 2. b. ] Notifies the
operator that the discharge is not eligible for coverage under this general
permit.
[ 2. When the operator is not in compliance with the conditions of the expiring or expired general permit the board may choose to do any or all of the following:
a. Initiate enforcement action based upon the 2009 general permit;
b. Issue a notice of intent to deny the new general permit. If the general permit is denied, the owner or operator would then be required to cease the activities authorized by the continued general permit or be subject to enforcement action for operating without a state permit;
c. Issue a new state permit with appropriate conditions; or
d. Take other actions authorized by the VSMP Regulation (9VAC25-870). ]
9VAC25-880-40. Virginia erosion and sediment control programs
Delegation of authorities to state and local programs.
VESCP requirements may be incorporated by reference into
the Stormwater Pollution Prevention Plan (SWPPP) required by 9VAC25-880-70 of this
state permit. Where a VESCP does not include one or more of the elements in
this section, then the operator must include those elements as part of the
SWPPP required by 9VAC25-880-70 of this permit. A VESCP is one that is approved
by the board, meets the requirements of 9VAC25-870-460 L and includes:
1. Requirements for construction site operators to implement
appropriate erosion and sediment control measures;
2. Requirements for construction site operators to control
waste such as discarded building materials, concrete truck washout, chemicals,
litter, and sanitary waste at the construction site that may cause adverse
impacts to water quality; and
3. Requirements for construction site operators to develop
and implement a SWPPP in accordance with 9VAC25-880-70 Section II.
A board-approved VSMP authority is authorized to administer requirements of this general permit, including but not limited to: (i) registration statement acceptance; (ii) fee collection; (iii) [ stormwater management ] plan review and approval; and (iv) permit compliance and enforcement dependent upon conditions established as part of the board approval.
9VAC25-880-50. [ State General ] permit
application (registration statement).
A. Deadlines for submitting registration statement. [ Any operator seeking coverage under this general permit, and that is required to submit a registration statement, shall submit a complete and accurate general VPDES permit registration statement in accordance with this section, which shall serve as a notice of intent for coverage under the general VPDES permit for discharges of stormwater from construction activities. ]
1. [ Except as provided in subdivision 3 of this
subsection, operators must certify that all information required in
subsection B of this section has been entered completely and accurately into
the available electronic database provided by the department and submit a
complete and accurate registration statement to the VSMP authority in
accordance with the requirements of this section prior to the issuance of
coverage under the general permit that authorizes the commencement of
land-disturbing activities (i.e., the initial disturbance of soils associated
with clearing, grading, excavation activities, or other construction
activities). New construction activities.
a. Any operator proposing a new stormwater discharge from construction activities shall submit a complete and accurate registration statement to the VSMP authority prior to the commencement of land disturbance.
b. Any operator proposing a new stormwater discharge from construction activities in response to a public emergency where the related work requires immediate authorization to avoid imminent endangerment to human health or the environment is authorized to discharge under this general permit, provided that:
(1) The operator submits a complete and accurate registration statement to the VSMP authority no later than 30 days after commencing land disturbance; and
(2) Documentation to substantiate the occurrence of the public emergency is provided with the registration statement.
c. Any operator proposing a new stormwater discharge associated with the construction of a single-family residence separately built, disturbing less than one acre and part of a larger common plan of development or sale, is authorized to discharge under this general permit and is not required to submit a registration statement or the department portion of the permit fee, provided that the stormwater management plan for the larger common plan of development or sale provides permanent control measures (i.e., stormwater management facilities) encompassing the single family residence. ]
2. [ Existing construction activities.
a. Any operator that was authorized to discharge under the general permit issued in 2009 and that intends to continue coverage under this general permit shall:
(1) Submit a complete and accurate registration statement to the VSMP authority on or before June 1, 2014; and
(2) Update its stormwater pollution prevention plan to comply with the requirements of this general permit no later than 60 days after the date of coverage under this general permit.
b. Any operator with an existing stormwater discharge associated with the construction of a single-family residence separately built, disturbing less than one acre and part of a larger common plan of development or sale, and that intends to continue coverage under this general permit, is authorized to discharge under this general permit and is not required to submit a registration statement or the department portion of the permit fee, provided that:
(1) The stormwater management plan for the larger common plan of development or sale provides permanent control measures (i.e., stormwater management facilities) encompassing the single-family residence; and
(2) The operator updates its stormwater pollution prevention plan to comply with the requirements of this general permit no later than 60 days after the date of coverage under this general permit.
3. ] For stormwater discharges from construction
activities where the operator changes, the new operator must [ certify
that all information required in subsection B of this section has been entered
completely and accurately into the available electronic database provided by
the department and ] submit a complete [ and accurate ]
registration statement or transfer [ agreement ] form [ to
the VSMP authority ] prior to assuming operational control over site
specifications or commencing work on-site.
[ 3. In order to continue state permit coverage,
operators of ongoing construction activity projects as of July 1, ] 2009
[ 2014, that received authorization to discharge for those
projects under the construction stormwater general permit issued in ] 2004
[ 2009 must:
a. ] Submit [ Certify that all
information required in subsection B of this section has been entered
completely and accurately into the available electronic database provided by
the department and submit a complete and accurate registration statement by ]
June 1, 2009 [ to the department 90 days prior to the
effective date of this general permit. Provided that a complete and
accurate registration statement is submitted by ] the June 1
reapplication date [ at least 90 days before the expiration date
of the existing state permit, the state permit application (registration
statement) fee will be waived for land-disturbing activities for which the department
initially issued state permit coverage on or after July 1, ] 2008
[ 2013; and
b. Update their stormwater pollution prevention plan to
comply with the requirements of this general permit within no later than
30 days after the date of coverage under this general permit. ]
4. Effective date of state permit coverage. The operator of
a construction activity is authorized to discharge stormwater under the terms
and conditions of this state permit 15 business days following submission of a
complete and accurate registration statement to the VSMP authority as the
administering entity for the board unless notification of coverage is made by
the department at an earlier time. For the purposes of this state permit, a
registration statement that is mailed is considered to be submitted once it is
postmarked. Operators are not authorized to discharge if the registration
statement is incomplete or incorrect, or if the discharge(s) was not eligible
for coverage under this state permit.
NOTE: A stormwater pollution prevention plan (SWPPP) must be
prepared in accordance with the requirements of the General Permit for
Stormwater Discharges from Construction Activities prior to submitting the
registration statement. By signing the registration statement the operator certifies
that the SWPPP has been prepared.
5. 4. Late notifications. Operators are not
prohibited from submitting registration statements after [ initiating
clearing, grading, excavation activities, or other land-disturbing activities
commencing land disturbance ]. When a late registration statement
is submitted, authorization for discharges shall not occur until coverage under
the general permit is issued. The department VSMP authority,
department, board, and the EPA [ reserves reserve ]
the right to take enforcement action for any unpermitted discharges that occur
between the commencement of [ construction land disturbance ]
and discharge authorization.
[ 5. Any discharge from a construction activity that
was previously permitted under the 2009 General Permit but failed to maintain
uninterrupted permit coverage is considered an unauthorized discharge. ]
B. Registration statement. The operator shall submit a
registration statement [ on to the VSMP authority ] the
official department form [ a form specified by the department ]
that shall contain the following information:
1. Name, [ contact, ] mailing address, telephone number, and email address [ if available ] of the construction activity operator. No more than one operator may receive coverage under each registration statement.
NOTE: [ The state General ] permit
[ coverage ] will be issued to this operator, and the
certification in subdivision [ 12 11 ] of this
subsection must be signed by the appropriate person associated with this operator;
2. Name and location [ if available ] of the
construction activity [ , including town, city, or county, and
latitude and longitude (degrees, minutes, seconds), and all off-site
support activities to be covered under the state permit. ] If a
street address is unavailable, provide latitude and longitude [ and
all off-site support activities to be covered under this general permit,
including city or county, and latitude and longitude in decimal degrees ];
3. Status of the [ construction ] activity: federal, state, public, or private;
4. Nature of the construction activity (e.g., commercial, industrial, residential, agricultural, oil and gas, etc.);
5. Name of the receiving water(s) and HUC [ . Direct discharges
to any receiving water identified as impaired on the ] 2008
[ 2012 § 305(b)/303(d) Water Quality Assessment Integrated
Report or for which a TMDL WLA has been established for stormwater discharges
from a construction activity shall be noted ];
6. If the discharge is through a municipal separate storm sewer
system (MS4), the name of the municipal [ separate storm sewer system ]
operator [ of the storm sewer ];
7. Estimated project start date and completion date;
8. Total land area of development and estimated area to be
disturbed by the construction activity (to the nearest [ one-tenth one-hundredth ]
of an acre);
9. Whether the area to be disturbed by the construction activity is part of a larger common plan of development or sale;
10. An indication of whether nutrient offsets are intended
to be acquired in accordance with § 62.1-44.15:35 of the Code of Virginia;
[ 10. Certifications. All information required by 9VAC25-880-50 B
has been entered into the electronic database provided by the department. By
signing the registration statement, the operator certifies that all information
has been entered completely and accurately. By signing the registration
statement, the operator certifies that all necessary approvals required by the
permit will be obtained prior to land disturbance;
11. 10. ] A stormwater pollution prevention
plan (SWPPP) must be prepared in accordance with the requirements of the
General [ VPDES ] Permit for Stormwater Discharges from
Construction Activities prior to [ submitting the registration statement land
disturbance ]. By signing the registration statement the operator
certifies that the SWPPP [ has been will be ] prepared
[ prior to land disturbance ]; and
[ 12. 11. ] The following
certification: "I certify under penalty of law that I have read and
understand this registration statement and that this document and all
attachments were prepared in accordance with a system designed to assure that
qualified personnel properly gathered and evaluated the information submitted. Based
on my inquiry of the person or persons who manage the system or those persons
directly responsible for gathering the information, the information submitted
is to the best of my knowledge and belief true, accurate, and complete. I am
aware that there are significant penalties for submitting false information
including the possibility of fine and imprisonment for knowing
violations."
C. The registration statement shall be signed in accordance
with 9VAC25-880-70, [ Section Part ] III K.
[ D. Where to submit. The registration statement shall
be submitted to the VSMP authority as the administering entity for the board.
E. Registration statements in the custody of the VSMP
authority or the department are subject to requests made pursuant to the
Virginia Freedom of Information Act (§ 2.2-3700 et seq. of the Code of
Virginia). ]
9VAC25-880-60. Termination of [ state general ]
permit coverage.
A. Requirements. The operator [ of the construction
activity ] shall [ certify that all information required in
subsection B of this section has been entered completely and accurately into
the electronic database provided by the department and shall ]
submit a notice of termination on the official department form [ on
a form specified by the department to the VSMP authority ]
after one or more of the following conditions have been met:
1. Necessary [ post-construction permanent ]
control measures included in the SWPPP for the site are in place and
functioning effectively and final stabilization has been achieved on all
portions of the site for which the operator is responsible [ . When
applicable, long-term responsibility and maintenance requirements for permanent
control measures shall be recorded in the local land records prior to the
submission of a notice of termination ];
2. Another operator has assumed control over all areas of the site that have not been finally stabilized and obtained coverage for the ongoing discharge;
3. Coverage under an alternative VPDES or state permit has been obtained; or
4. For residential construction only, temporary [ soil ] stabilization has been completed and the residence has been transferred to the homeowner.
The notice of termination must should be
submitted [ within no later than ] 30 days [ of
after ] one of the above conditions being met. Authorization to
discharge terminates at midnight on the date that the notice of termination is
submitted [ unless otherwise notified by the VSMP authority or the
department ] for the conditions set forth in subdivisions 2
through 4 of this subsection [ unless otherwise notified by the VSMP
authority or the department ]. Termination of authorizations to
discharge for the conditions set forth in subdivision 1 of this subsection
shall be effective upon notification from the department that the provisions of
subdivision 1 of this subsection have been met or 60 days after submittal of
the notice of terminations, whichever occurs first.
B. Notice of termination. The notice of termination shall contain the following information:
1. Name, [ contact, ] mailing address, telephone number, and email address [ if available ] of the construction activity operator.
2. Name and location [ if available ] of the
construction activity [ covered under this general permit, including
city or county, and latitude and longitude in decimal degrees ]. If
a street address is unavailable, latitude and longitude shall be provided.
3. The stormwater general permit registration
number.
4. The basis for submission of the notice of termination, pursuant to subsection A of this section.
5. Where applicable, a list of the [ on-site and
off-site ] permanent control measures (both structural and
nonstructural) that were installed [ or employed to meet the post
development stormwater quality criteria at the construction activity site
to comply with the stormwater management technical criteria ]. For
each permanent control measure that was installed [ or
employed ], the following information shall be included:
a. [ Where applicable, the following information
related to onsite control measures: (1) Type The type ] of
[ onsite ] permanent control measure installed and the
date that it became functional as a permanent control measure;
[ b. ] Geographic location (county or city and
Hydrologic Unit Code); [ (2) Latitude and longitude ]
may additionally be included if available; [ (in degrees,
minutes, and seconds to the nearest 15 seconds) of the permanent control
measure outfall The location if available of the permanent control
measure, including city or county, and latitude and longitude in decimal
degrees ];
[ c. ] Waterbody the control measure discharges
into; and [ The receiving water of the permanent control measures;
and
d. ] Number [ The number of total
and impervious acres treated by the permanent control measure (to
the nearest one-tenth of an acre).
(3) Construction activity acres treated onsite (to the
nearest one tenth of an acre); and
(4) Construction activity nutrient reductions achieved
onsite (lbs. per acre per year).
6. Where applicable, the following information related to participation in a regional stormwater management plan. For each regional stormwater management facility, the following information shall be included:
b. Where applicable, the following information related
to offsite control measures:
(1) Type of offsite permanent control measure to which
the construction activity contributes (e.g., a permanent control measure
installed as part of a larger common plan of development or a permanent control
measure installed in accordance with a comprehensive stormwater management plan
adopted pursuant to 4VAC50-60-929VAC25-870-92);
(2) Approximate latitude and longitude (in degrees,
minutes, and seconds to the nearest 15 seconds) of the offsite control measure;
and
(3) Construction activity nutrient reductions achieved
offsite (lbs. per acre per year).
a. ] Type [ The type of regional
facility ] or facilities [ to which the site contributes;
b. ] Geographic location of any regional facility to
which the site contributes (county or city and Hydrologic Unit Code);
[ The location if available of the regional facility, including city or
county, and latitude and longitude in decimal degrees; and
c. ] Geographic location of the site (county or city
and Hydrologic Unit Code). Latitude and longitude may additionally be included
if available; and [ The number of total and impervious site acres
treated by the regional facility (to the nearest one-tenth of an acre). ]
d. Number of acres treated by a regional facility.
[ 7. c. ] Where applicable, the
following information related to perpetual nutrient [ offsets ]
credits that were acquired in accordance with § 62.1-44.15:35
of the Code of Virginia:
[ (1) Name of the nonpoint source nutrient bank
from which nutrient credits were acquired. a. The name of the nonpoint
nutrient credit generating entity from which perpetual nutrient credits were
acquired ]; and
[ (2) Number b. The number ] of
[ perpetual ] nutrient credits acquired (lbs. per acre per
year).
a. Name of the broker from which offsets were acquired;
b. Geographic location (county or city and Hydrologic Unit
Code) of the broker's offset generating facility;
c. Number of nutrient offsets acquired (lbs. per acre per
year); and
d. Nutrient reductions achieved on site (lbs. per acre per
year).
[ 6. Any instrument recorded for the long term
maintenance of any permanent stormwater management facilities, required
pursuant to 9VAC25-870-112 has been submitted to the VSMP authority.
8. 7. ] The following certification: "I
certify under penalty of law that I have read and understand this notice of
termination and that this document and all attachments were prepared in
accordance with a system designed to assure that qualified personnel properly
gathered and evaluated the information submitted. Based on my inquiry of the
person or persons who manage the system or those persons directly responsible
for gathering the information, the information submitted is to the best of my
knowledge and belief true, accurate, and complete. I am aware that there are
significant penalties for submitting false information including the
possibility of fine and imprisonment for knowing violations."
C. The notice of termination shall be signed in accordance
with 9VAC25-880-70 [ Section Part ] III K.
[ D. Where to submit. The notice of termination shall
be submitted to the VSMP authority as the administering entity for the board.
E. D. ] Termination by the [ department
in coordination with the VSMP authority board ]. The department
in coordination with the VSMP authority board may terminate coverage
under this [ state general ] permit during its term and
require application for an individual permit or deny a [ state general ]
permit renewal application on its own initiative in accordance with the Act,
this chapter, and [ the VSMP Regulation, ] 9VAC25-870.
9VAC25-880-70. General permit.
Any operator whose registration statement is accepted by the department
board [ or its designated authority ] will
receive the following [ state general ] permit and
shall comply with the requirements in it and be subject to all requirements
of the Virginia Stormwater Management Act and the Virginia Stormwater
Management Program (VSMP) Regulations (9VAC25-870) [ contained ]
therein [ and be subject to all requirements of 9VAC25-870 ].
[ No more than one operator may receive coverage under each
registration statement. ]
General Permit No.: VAR10
Effective Date: July 1, 2009 2014
Expiration Date: June 30, 2014 2019
GENERAL [ VPDES ] PERMIT FOR DISCHARGES OF STORMWATER FROM CONSTRUCTION ACTIVITIES
AUTHORIZATION TO DISCHARGE UNDER THE VIRGINIA STORMWATER MANAGEMENT PROGRAM AND THE VIRGINIA STORMWATER MANAGEMENT ACT
In compliance with the provisions of the Clean Water Act, as
amended, and pursuant to the Virginia Stormwater Management Act and [ attendant ]
regulations [ adopted pursuant thereto ], operators of
construction activities [ covered by this state permit with stormwater
discharges ] are authorized to discharge to state surface
waters, including discharges to a regulated MS4 system, within the boundaries
of the Commonwealth of Virginia, except those specifically named in State Water
Control Board regulations that prohibit such discharges.
The authorized discharge shall be in accordance with this
cover page, [ Section Part ] I - Discharge Authorization
and Special Conditions, [ Section Part ] II -
Stormwater Pollution Prevention Plan, and [ Section Part ]
III - Conditions Applicable to All [ State VPDES ]
Permits as set forth herein.
[ SECTION PART ] I
DISCHARGE AUTHORIZATION AND SPECIAL CONDITIONS
A. Coverage under this [ state general ]
permit.
1. During the period beginning with the date of coverage under
this general permit and lasting until the [ state general ]
permit's expiration date, the operator is authorized to discharge stormwater
from [ the following ] construction activities [ .:
a. New construction activities. Construction activities
for which initial permit coverage is sought under this permit provided permit
compliance is maintained or construction activities previously covered under
the 2009 Virginia General Permit for Stormwater Discharges for Construction
Activities and for which a registration statement was submitted in accordance
with Section III M of the 2009 permit in order to maintain uninterrupted
coverage.
b. Previously covered construction activities.
Construction activities that have obtained VSMP permit coverage under the 2009
Construction Activities and submitted a registration statement in accordance
with Section III M of the 2009 permit in order to maintain uninterrupted permit
coverage.
c. Emergency related construction activities.
Construction activities in response to a public emergency (e.g., natural
disaster, disruption in essential public services), and the related work
requires immediate authorization to avoid imminent endangerment to human
health, public safety, or the environment. The operator shall have coverage
under this permit in order to address these public emergencies provided that:
(1) The operator advises the VSMP authority of the
construction activity within seven days of commencing land disturbance;
(2) State permit coverage is applied for within 30 days
of commencing the land disturbing activity; and
(3) Documentation is provided with the registration
statement to substantiate the occurrence of the public emergency. ]
2. This [ state general ] permit may
also authorize authorizes stormwater discharges from support
activities (e.g., concrete or asphalt batch plants, equipment staging yards,
material storage areas, excavated material disposal areas, borrow areas)
located on-site or off-site provided that:
a. The support activity is directly related to the
construction site that is required to have activity [ applying
for state that is required to have general ] permit
coverage [ for discharges of stormwater ] associated with
[ from construction ] activity [ activities ];
b. The support activity is not a commercial operation [ , ]
serving [ or does not nor does it ] serve
multiple unrelated construction [ projects activities ]
by different operators [ , and does not operate beyond the completion
of ] the construction activity at [ the last
construction project it supports ]; and
[ c. The support activity does not operate beyond the completion of the last construction activity it supports;
c. d. ] The support activity is
identified in the registration statement at the time of [ general
permit ] coverage;
[ c. d. e. ] Appropriate
control measures are identified in a stormwater pollution prevention plan and
implemented to address the discharges from the support activity areas.;
and
[ e. f. ] All applicable
state, federal, and local approvals are obtained for the support activity.
3. There shall be no discharge of floating solids or visible
foam that contravenes established standards or interferes directly or
indirectly with designated uses of surface waters.
B. Limitation Limitations on coverage.
1. Post-construction discharges. This [ state general ]
permit does not authorize stormwater discharges that originate from the site
after construction activities have been completed and the site, including any temporary
support activity site sites covered under the [ general ]
permit registration, has undergone final stabilization.
Post-construction industrial stormwater discharges may need to be covered by a
separate VPDES permit [ and permit coverage has been terminated ].
Post-construction industrial stormwater discharges may need to be covered by
a separate VPDES permit.
[ 2. Discharges mixed with nonstormwater. This general ]
state [ permit does not authorize discharges that are mixed with
sources of nonstormwater, other than those discharges that are identified
in ] Section I D 2 (Exceptions to prohibition of nonstormwater
discharges) [ Part I E (Authorized nonstormwater discharges) ]
and are in compliance with Section II D 5 (Nonstormwater discharge
management) [ this general permit. ]
[ 3. 2. ] Discharges covered by another
state permit. This [ state general ] permit does not
authorize [ stormwater discharges associated with construction activity
discharges of stormwater from construction activities ] that have
been covered under an individual permit or required to obtain coverage under an
alternative general permit.
4. TMDL limitation. Discharges to waters for which a
wasteload allocation (WLA) for a pollutant has been established in an approved
"total maximum daily load" (TMDL) that would apply to stormwater
discharges from a construction activity are not eligible for coverage under
this state permit unless the stormwater pollution prevention plan (SWPPP)
developed by the operator is consistent with the requirements related to TMDLs
contained in Section II D 6.
5. Impaired waters limitation. Discharges to waters that
have been identified as impaired in the 2008 § 305(b)/303(d) Water Quality
Assessment Integrated Report are not eligible for coverage under this state
permit unless the operator implements strategies and control measures
consistent with Sections I H and II D 7.
[ 3. Limitations on coverage for discharges to
impaired waters. This only applies when construction activities discharge or
are reasonably expected to discharge an applicable observed source identified
in the 2012 § 305(b)/303(d) Water Quality Integrated Report or a pollutant
of concern identified in a TMDL approved prior to July 1, 2014.
a. Discharges to impaired waters, including discharges
to surface waters located within a TMDL watershed, are not eligible for
coverage under this general permit unless the following requirements are
implemented:
(1) The impaired water(s), associated impairment(s),
TMDL name(s), and TMDL pollutant(s) of concern when applicable shall be
identified in the registration statement and in the SWPPP;
(2) The operator shall develop, implement, and maintain
a SWPPP that minimizes applicable observed sources identified in the 2012
§ 305(b)/303(d) Water Quality Assessment Integrated Report, minimizes
pollutants of concern identified in a TMDL approved prior to July 1, 2014, and
is consistent with the assumptions and requirements of all associated TMDL
wasteload allocations when applicable; and
(3) The following modifications to the SWPPP inspection
schedule shall be implemented:
(a) Inspections shall be conducted at a frequency of:
(i) At least once every four days; or
(ii) At least once every seven days and no later than 48
hours following any measurable storm event. In the event that a measurable
storm event occurs when there are more than 48 hours between normal working
days, the inspection shall be conducted on the next working day.
(b) Where areas have been temporarily stabilized or
runoff is unlikely due to winter conditions (e.g., the site is covered with
snow or ice, or continuous frozen ground exists), the inspection frequency may
be reduced to once every 30 days. If unexpected weather conditions (such as
above freezing temperature or rain or snow events) make discharges likely, the
operator shall immediately resume the regular inspection frequency.
(c) Representative inspections utilized by utility line
installation, pipeline construction, or other similar linear construction
activities in Section II F 2 c shall also inspect all outfalls discharging
directly to an impaired water.
(4) The requirements of Sections I B 3 a (1) through I B
3 a (3) shall be implemented for:
(a) All construction activities outside of Tidewater
Virginia, as defined in § 62.1-44.15:68 of the Code of Virginia, that
discharge to a surface water in the Chesapeake Bay watershed and disturb
greater than or equal to 20 acres;
(b) All construction activities inside of Tidewater
Virginia, as defined in § 62.1-44.15:68 of the Code of Virginia, that
discharge to a surface water in the Chesapeake Bay watershed and disturb
greater than or equal to 10 acres;
(c) All construction activities that discharge to a
surface water located within a TMDL watershed other than the Chesapeake Bay
watershed and disturb greater than or equal to five acres; and
(d) All construction activities that discharge directly
to an impaired water. For the purposes of this permit, a construction activity
will be considered to discharge directly to an impaired water if the first
surface water to which it discharges has been identified in the 2012
§ 305(b)/303(d) Water Quality Assessment Integrated Report as not meeting
an applicable water quality standard. For discharges that enter a storm sewer
system prior to discharge, the surface water to which the operator discharges
is the first surface water that receives the stormwater discharge from the
storm sewer system.
b. Discharges to impaired waters, including discharges
to surface waters located within a TMDL watershed, where sediment, a sediment
related parameter (e.g., total suspended solids or turbidity) or nutrients
(e.g., nitrogen or phosphorus) are an applicable observed source identified in
the 2012 § 305(b)/303(d) Water Quality Assessment Integrated Report or a
pollutant of concern identified in a TMDL approved prior to July 1, 2014, shall
also implement the following requirements:
(1) Permanent or temporary soil stabilization shall be
applied to denuded areas within seven days after final grade is reached on any
portion of the site; and
(2) Nutrients shall be applied in accordance with
manufacturer's recommendations and shall not be applied during rainfall events.
4. Limitations on coverage for new discharges to
exceptional waters identified in 9VAC25-260-30 A 3 c. Discharges from new
construction activities to exceptional waters are not eligible for coverage
under this general permit unless the following requirements are implemented:
a. The exceptional water shall be identified in the
registration statement and in the SWPPP;
b. Permanent or temporary soil stabilization shall be
applied to denuded areas within seven days after final grade is reached on any
portion of the site;
c. The following modifications to the SWPPP inspection
schedule shall be implemented;
(1) Inspections shall be conducted at a frequency of:
(a) At least once every four days; or
(b) At least once every seven days and no later than 48
hours following any measurable storm event. In the event that a measurable
storm event occurs when there are more than 48 hours between normal working
days, the inspection shall be conducted on the next working day.
(c) Where areas have been temporarily stabilized or
runoff is unlikely due to winter conditions (e.g., the site is covered with
snow or ice, or continuous frozen ground exists), the inspection frequency may
be reduced to once every 30 days. If unexpected weather conditions (such as
above freezing temperature or rain or snow events) make discharges likely, the
operator shall immediately resume the regular inspection frequency.
(2) Representative inspections utilized by utility line
installation, pipeline construction, or other similar linear construction
activities in Section II F 2 c shall also inspect all outfalls discharging
directly to an exceptional water.
5. There shall be no discharges of floating solids or
visible foam in other than trace amounts.
4. Impaired waters and TMDL limitation. Discharges of stormwater from construction activities to surface waters identified as impaired in the 2012 § 305(b)/303(d) Water Quality Assessment Integrated Report or for which a TMDL wasteload allocation has been established and approved prior to the term of this general permit for (i) sediment or a sediment-related parameter (i.e., total suspended solids or turbidity) or (ii) nutrients (i.e., nitrogen or phosphorus) are not eligible for coverage under this general permit unless the operator develops, implements, and maintains a SWPPP that minimizes the pollutants of concern and, when applicable, is consistent with the assumptions and requirements of the approved TMDL wasteload allocations. In addition, the operator shall implement the following items:
a. The impaired water(s), approved TMDL(s), and pollutant(s) of concern, when applicable, shall be identified in the SWPPP;
b. Permanent or temporary soil stabilization shall be applied to denuded areas within seven days after final grade is reached on any portion of the site;
c. Nutrients shall be applied in accordance with manufacturer's recommendations or an approved nutrient management plan and shall not be applied during rainfall events; and
d. The applicable SWPPP inspection requirements specified in Part II F 2 shall be amended as follows:
(1) Inspections shall be conducted at a frequency of (i) at least once every four business days or (ii) at least once every five business days and no later than 48 hours following a measurable storm event. In the event that a measurable storm event occurs when there are more than 48 hours between business days, the inspection shall be conducted on the next business day; and
(2) Representative inspections used by utility line installation, pipeline construction, or other similar linear construction activities shall inspect all outfalls discharging to surface waters identified as impaired or for which a TMDL wasteload allocation has been established and approved prior to the term of this general permit.
5. Exceptional waters limitation. Discharges of stormwater from construction activities not previously covered under the general permit issued in 2009 to exceptional waters identified in 9VAC25-260-30 A 3 c are not eligible for coverage under this general permit unless the operator implements the following:
a. The exceptional water(s) shall be identified in the SWPPP;
b. Permanent or temporary soil stabilization shall be applied to denuded areas within seven days after final grade is reached on any portion of the site;
c. Nutrients shall be applied in accordance with manufacturer's recommendations or an approved nutrient management plan and shall not be applied during rainfall events; and
d. The applicable SWPPP inspection requirements specified in Part II F 2 shall be amended as follows:
(1) Inspections shall be conducted at a frequency of (i) at least once every four business days or (ii) at least once every five business days and no later than 48 hours following a measurable storm event. In the event that a measurable storm event occurs when there are more than 48 hours between business days, the inspection shall be conducted on the next business day; and
(2) Representative inspections used by utility line installation, pipeline construction, or other similar linear construction activities shall inspect all outfalls discharging to exceptional waters.
6. There shall be no discharge of floating solids or visible foam in other than trace amounts. ]
C. Commingled discharges. Any discharge authorized by a
different state or VPDES permit may be commingled with discharges authorized by
this state permit. Discharges authorized by this [ general ]
permit may be commingled [ with other sources of stormwater that
are not required to be covered under a state permit, so long as the commingled
discharge is in compliance with this general permit ]. Discharges
authorized by a separate [ VSMP state ] or
VPDES permit may be commingled with discharges authorized by this [ general ]
permit [ so long as all such discharges comply with all
applicable state and VPDES permit requirements ].
D. Prohibition of nonstormwater discharges. 1. Except
as provided in Sections I A 2, I C and I D 2 [ Sections
Parts ] I A 2, I C and I E, all discharges covered by this
[ state general ] permit shall be composed entirely of
stormwater associated with construction [ activity activities ].
All other discharges including the following are prohibited:
1. Wastewater from washout of concrete [ ,
unless managed by an appropriate control as described at Section II A 2 d (5)
(e).; ]
2. Wastewater from [ the ] washout and cleanout of stucco, paint, form release oils, curing compounds, and other construction materials;
3. Fuels, oils, or other pollutants used in vehicle and equipment operation and maintenance;
4. Oils, toxic substances, or hazardous substances from spills or other releases; and
5. Soaps [ and, ] solvents
[ , or detergents ] used in equipment and vehicle washing.
2. The following nonstormwater discharges from active
construction sites are authorized by this state permit provided the
nonstormwater component of the discharge is in compliance with Section II D 5
(Nonstormwater discharges):
E. Authorized nonstormwater discharges. The following nonstormwater discharges from construction activities are authorized by this [ general ] permit when discharged in compliance with this [ general ] permit:
a. 1. Discharges from firefighting activities;
b. 2. Fire hydrant flushings;
c. 3. Waters used to wash vehicles [ or
equipment ] where [ soaps, solvents, or ] detergents are
not have not been used and the wash water has been [ filtered,
settled, or similarly ] treated [ prior to discharge ];
d. 4. Water used to control dust that has
been filtered, settled, or similarly treated prior to discharge;
e. 5. Potable water sources, including
uncontaminated waterline flushings;
f. 6. Routine external building wash down
[ which does not use detergents where soaps ],
solvents or [ other wash chemicals and that have
detergents have not been used and the wash water has ] been
filtered, settled, or similarly treated prior to discharge;
g. 7. Pavement [ washwaters wash
waters ] where spills or leaks of toxic or hazardous materials have
not occurred (unless all spilled material has been removed) (or where
all spilled [ or leaked ] material has been removed
[ prior to washing) ] and; where [ soaps,
solvents, or ] detergents [ , solvents, or other wash
chemicals are have ] not [ been ] used
[ ,; ] and where the [ washwater
wash water ] has been filtered, settled, or similarly treated prior
to discharge;
h. 8. Uncontaminated air conditioning or
compressor condensate;
i. 9. Uncontaminated ground water or spring
water;
j. 10. Foundation or footing drains where flows
are not contaminated with process materials such as solvents;
k. 11. Uncontaminated excavation dewatering, including
dewatering of trenches and excavations that have been filtered, settled, or
similarly treated prior to discharge; and
l. 12. Landscape irrigation.
E. Releases of hazardous substances or oil in excess of
reportable quantities. The discharge of hazardous substances or oil in the
stormwater discharges from the construction site shall be prevented or
minimized in accordance with the stormwater pollution prevention plan for the
site. This state permit does not relieve the state permittee of the reporting
requirements of 40 CFR Part 110, 40 CFR Part 117 and 40 CFR Part 302 or
§ 62.1-44.34:19 of the Code of Virginia.
Where a release containing a hazardous substance or oil in
an amount equal to or in excess of a reportable quantity established under
either 40 CFR Part 110, 40 CFR Part 117, 40 CFR Part 302, or
§ 62.1-44.34.19 of the Code of Virginia occurs during a 24-hour period:
1. The operator is required to notify the department and the
VSMP authority in accordance with the requirements of Section III G as soon as
he has knowledge of the discharge;
2. Where a release enters a municipal separate storm sewer
system (MS4), the operator shall also notify the operator of the MS4; and
3. The stormwater pollution prevention plan required under
Section II D of this state permit must be reviewed by the operator to identify
measures to prevent the reoccurrence of such releases and to respond to such
releases, and the plan must be modified where appropriate within seven calendar
days of knowledge of a release.
F. Spills. This state permit does not authorize the
discharge of hazardous substances or oil resulting from an on-site spill.
G. F. Termination of [ state general ]
permit coverage. [ Coverage under this state permit may be terminated
in accordance with 9VAC25-880-60.
1. The operator of the construction activity shall submit a notice of termination in accordance with 9VAC25-880-60 to the VSMP authority after one or more of the following conditions have been met:
a. Necessary permanent control measures included in the SWPPP for the site are in place and functioning effectively and final stabilization has been achieved on all portions of the site for which the operator is responsible. When applicable, long term responsibility and maintenance requirements shall be recorded in the local land records prior to the submission of a notice of termination;
b. Another operator has assumed control over all areas of the site that have not been finally stabilized and obtained coverage for the ongoing discharge;
c. Coverage under an alternative VPDES or state permit has been obtained; or
d. For residential construction only, temporary soil stabilization has been completed and the residence has been transferred to the homeowner.
2. The notice of termination should be submitted no later than 30 days after one of the above conditions in subdivision 1 of this subsection are met. Authorization to discharge terminates at midnight on the date that the notice of termination is submitted for the conditions set forth in subdivisions 1 b through 1 d of this subsection. Termination of authorizations to discharge for the conditions set forth in subdivision 1 a of this subsection shall be effective upon notification from the department that the provisions of subdivision 1 a of this subsection have been met or 60 days after submittal of the notice of termination, whichever occurs first.
3. The notice of termination shall be signed in accordance with Part III K of this general permit. ]
H. G. Water quality protection.
1. The operator must select, install, implement and maintain
control measures as identified in the SWPPP at the construction site
that minimize pollutants in the discharge as necessary to ensure that the
operator's discharge does not cause or contribute to an excursion above any
applicable water quality standards standard.
2. If it is determined by the department [ in
consultation with the State Water Control Board ] at any time
that the operator's stormwater discharges are causing,
have reasonable potential to cause, or contribute are
contributing to an excursion above any applicable water quality standard,
the department shall, in consultation with the VSMP authority, may
take appropriate enforcement action and require the operator to:
a. Modify [ or implement additional ] control
measures in accordance with [ Section Part ] II C
B to adequately address the identified water quality concerns;
b. Submit valid and verifiable data and information that are representative of ambient conditions and indicate that the receiving water is attaining water quality standards; or
c. [ Cease discharges of pollutants from construction
activity and submit Submit ] an individual permit application
[ according to in accordance with ] 9VAC25-870-410 B 3.
All written responses required under this chapter must include
a signed certification consistent with [ Section Part ]
III K.
[ SECTION PART ] II
STORMWATER POLLUTION PREVENTION PLAN
[ A stormwater pollution prevention plan (SWPPP) shall be developed prior to the submission of a registration statement and implemented for the construction activity, including any support activity, covered by this general permit. SWPPPs shall be prepared in accordance with good engineering practices. Construction activities that are part of a larger common plan of development or sale and disturb less than one acre may utilize a SWPPP template provided by the department and need not provide a separate stormwater management plan if one has been prepared and implemented for the larger common plan of development or sale.
The SWPPP requirements of this general permit may be fulfilled by incorporating by reference other plans such as a spill prevention control and countermeasure (SPCC) plan developed for the site under § 311 of the federal Clean Water Act or best management practices (BMP) programs otherwise required for the facility provided that the incorporated plan meets or exceeds the SWPPP requirements of Part II A. All plans incorporated by reference into the SWPPP become enforceable under this general permit. If a plan incorporated by reference does not contain all of the required elements of the SWPPP, the operator must develop the missing elements and include them in the SWPPP.
Any operator that was authorized to discharge under the general permit issued in 2009, and that intends to continue coverage under this general permit, shall update its stormwater pollution prevention plan to comply with the requirements of this general permit no later than 60 days after the date of coverage under this general permit. ]
A. Stormwater [ Pollution Prevention Plan ] Framework.
[ pollution prevention plan contents. The SWPPP shall include the
following items: ]
[ 1. A stormwater pollution prevention plan (SWPPP)
shall be developed prior to land disturbance ] submission of
a registration statement and implemented [ for the construction
activity covered by this state permit. SWPPPs shall be prepared in accordance
with good engineering practices. Construction activities that are part of a
common plan of development and disturb less than one acre may utilize a SWPPP
template provided by the department and need not provide a separate stormwater
management plan is one has been prepared and implemented for the planned
development.
2. The SWPPP shall include: ]
a. Identify potential sources of pollutants that may
reasonably be expected to affect the quality of stormwater discharges from the
construction site;
b. Describe control measures that will be used to minimize
pollutants in stormwater discharges from the construction site; and
c. Comply with the terms and conditions of this state permit.
[ a. General Information.
(1) A copy of the Registration for Coverage under the
General Permit for Discharges of Stormwater for Construction Activities signed
in accordance with 9VAC25-870-370;
(2) Upon receipt of coverage, a copy of the Notice of
Coverage under the General Permit for Discharges of Stormwater from
Construction Activities;
(3) A copy of the General Permit for Discharges of
Stormwater from Construction Activities;
(4) A narrative description of the nature of the
construction activity, including the function of the project (e.g., low density
residential, shopping mall, highway, etc.);
(5) A legible site plan identifying:
(a) Directions of stormwater flow and approximate slopes
anticipated after major grading activities;
(b) Limits of land disturbance including steep slopes
and natural buffers around surface waters that will not be disturbed;
(c) Locations of major structural and nonstructural
control measures including sediment basins and traps, perimeter dikes, sediment
barriers, and other measures intended to filter or similarly treat sediment
that will be installed between disturbed areas and the undisturbed vegetated
areas, in order to increase sediment removal and maximize stormwater
infiltration;
(d) Locations of surface waters;
(e) Locations where concentrated stormwater is
discharged;
(f) Location of the on site rain gauge, or a description
of the methodology to identify measurable storm events established in
consultation with the VSMP authority, used to identify a measurable storm event
for inspection purposes; and
(g) Locations of on site and off site, when applicable
and when required by the VSMP authority, support activities, including: (i)
areas where equipment and vehicle washing, wheel wash water, and other wash
water is to occur; (ii) storage areas for chemicals such as acids, fuels,
fertilizers and other lawn care chemicals; (iii) concrete wash out areas; (iv)
vehicle fueling and maintenance areas; (v) sanitary waste facilities, including
those temporarily placed on the construction site; and (vi) construction waste
storage.
(6) Previously covered construction activities, as
identified in Section I A 1 b, shall review and update their SWPPP no later
than 30 days following permit coverage to include the required information
listed in Section II A 2 a.
b. Erosion and Sediment Control Plan.
(1) An erosion and sediment control plan or an agreement
in lieu of a plan, as defined in 9VAC25-840-10, approved by a board approved
VESCP authority or, where appropriate, an erosion and sediment control plan
designed in accordance with annual standards and specifications approved by the
department. The operator of any land disturbing activity that is not required
to obtain erosion and sediment control plan approval from a VESCP authority or
adopts department approved annual standards and specifications shall submit the
erosion and sediment control plan to the department for review and approval
prior to land disturbance. Plan approval prior to land disturbance does not
apply to emergency related construction activities.
(2) For off site support activities such as borrow or
fill areas, all required erosion and sediment control plans approved by a VESCP
authority or, where appropriate, an erosion and sediment control plan designed
in accordance with annual standards and specifications approved by the
department. The operator of any land disturbing activity that is not required
to obtain erosion and sediment control plan approval from a VESCP authority or
adopts department approved annual standards and specifications shall submit the
erosion and sediment control plan to the department for review and approval
prior to land disturbance.
(3) All erosion and sediment control plans shall include
a statement describing the maintenance responsibilities required for the
erosion and sediment controls utilized.
(4) Unless there is evidence as the result of an
inspection as required under Section II F, an approved and properly implemented
erosion and sediment control plan; an agreement in lieu of a plan approved by
the VESCP authority without exception; or an erosion and sediment control plan
designed and implemented in accordance with annual standards and specifications
approved by the department that adequately:
(a) Controls the volume and velocity of stormwater
runoff within the site to minimize soil erosion;
(b) Controls stormwater discharges, including both peak
flow rates and total stormwater volume, to minimize erosion at outlets and to
minimize downstream channel and stream bank erosion;
(c) Minimizes the disturbance of steep slopes;
(d) Minimizes the amount of soil exposed during
construction activity;
(e) Minimizes sediment discharges from the site in a
manner that addresses the amount, frequency, intensity, and duration of
precipitation, the nature of resulting stormwater runoff and soil
characteristics, including the range of soil particle sizes expected to be
present on the site;
(f) Provides and maintains natural buffers around
surface waters, directs stormwater to vegetated areas to increase sediment
removal, and maximizes stormwater infiltration, unless infeasible;
(g) Minimizes soil compaction and preserves topsoil
where feasible;
(h) Ensures that stabilization will begin immediately
upon installation of earthen structures such as dams, dikes, and diversions and
that stabilization of denuded areas shall be initiated immediately upon
reaching final grade or for areas that may not be at final grade but will
remain dormant for longer than 14 days. Temporary stabilization shall be
installed within seven days of initiation; and
(i) Discharges stormwater from the surface of basins and
other impoundments when the impoundment is designed to include wet storage and
is designed to discharge above the permanent pool elevation.
(5) Previously covered construction activities, as
identified in Section I A 1 b, shall implement the inspection requirements in
Section II F and update their erosion and sediment control plan no later than
30 days following permit coverage to include the required modifications
resulting from the inspection requirements.
c. Stormwater Management Plan. A stormwater management
plan from the appropriate VSMP authority as authorized under the Virginia
Stormwater Management Program Regulations, 9VAC25-870. The operator of any land
disturbing activity that is not required to obtain stormwater management plan
approval from a VSMP authority or is not required to adopt department approved
annual standards and specifications shall submit the stormwater management plan
to the department for review and approval prior to land disturbance. Plan
approval prior to land disturbance does not apply to emergency related
construction activities.
d. Pollution Prevention Plan. A pollution prevention
plan that addresses expected pollutant generating activities from both on site
and off site support activities covered under the general permit that may
reasonably be expected to affect the quality of stormwater discharges. In order
to comply with 9VAC25-870-56, the pollution prevention plan shall:
(1) Identify the potential pollutant generating
activities and the pollutant that is expected to be exposed to stormwater for
on site and off site activities, including support activities;
(2) Describe the location where the pollutant generating
activities will occur; or if identified on the site plan, reference to the site
plan;
(3) Identify all nonstormwater discharges, as authorized
in Section I E of this permit, that are or will be commingled with stormwater
discharges from the construction activity at the site;
(4) Identify the person responsible for the pollution
prevention activities for each pollutant generating activity (if other than the
person listed as the qualified personnel);
(5) Describe procedures and practices that will be
implemented to:
(a) Prevent and respond to leaks, spills and other
releases including (i) procedures for expeditiously stopping, containing, and
cleaning up spills, leaks, and other releases; and (ii) procedures for
reporting leaks, spills, and other releases in accordance with Section III G;
(b) Eliminate the discharge of spilled and leaked fuels
and chemicals from vehicle fueling and maintenance activities (e.g., providing
secondary containment such as spill berms, decks, spill containment pallets,
providing cover where appropriate, and having spill kits readily available);
(c) Prevent the discharge of soaps, detergents,
solvents, and wash water from construction materials, such as clean up of
stucco, paint form release oils, and curing compounds, by providing (i) cover
(e.g., plastic sheeting or temporary roofs) to prevent contact with stormwater;
(ii) collection and proper disposal in a manner to prevent contact with
stormwater; and (iii) a similarly effective means designed to prevent discharge
of these pollutants.
(d) Minimize the discharge of pollutants from equipment
and vehicle washing, wheel wash water and other types of washing (e.g.,
locating activities away from surface waters and stormwater inlets or
conveyance and directing wash waters to sediment basins or traps, using
filtration devices such as filter bags or sand filters or using similarly
effective controls);
(e) Direct concrete wash water into a leak proof
container or leak proof settling basin that is designed so that no overflows
can occur due to inadequate sizing or precipitation. Hardened concrete wastes
shall be removed and disposed of in a manner consistent with the handling of
other construction wastes. Liquid concrete wastes shall be removed and disposed
of in a manner consistent with the handling of other construction wash waters
and shall not be discharged to surface waters;
(f) Minimize the discharge of pollutants from storage,
handling, and disposal of construction products, materials, and wastes
including (i) building products such as asphalt sealants, copper flashing,
roofing materials, adhesives, concrete admixtures; (ii) pesticides, herbicides,
insecticides, fertilizers, and landscape materials; and (iii) construction and domestic
wastes such as packaging materials, scrap construction materials, masonry
products, timber, pipe and electrical cuttings, plastics, styrofoam, concrete,
and other trash or building materials;
(g) Prevent the discharge of fuels, oils, and other
petroleum products, hazardous or toxic wastes, and sanitary wastes; and
(h) Address any other discharges from the potential
pollutant generating activity not addressed above.
(6) The pollution prevention plan shall describe
procedures for providing pollution prevention awareness of all applicable
wastes, including any wash water, disposal practices and applicable disposal
locations of such wastes, to personnel in order to comply with the conditions
of this permit. The operator shall implement the procedures described in the
SWPPP.
(7) Previously covered construction activities, as
identified in Section I A 1 b, shall review and update their pollution
prevention plan no later than 30 days following permit coverage to ensure
compliance with these permit conditions.
e. Applicable state or local programs. Certain
requirements of this general permit may be fulfilled by incorporating by
reference other plans such as a spill prevention control and countermeasure
(SPCC) plan developed for the site under § 311 of the federal Clean Water
Act or BMP programs otherwise required for the facility provided that the
incorporated plan meets or exceeds the SWPPP requirements of Section II A 2 a.
All plans incorporated by reference into the SWPPP become enforceable under
this permit. If a plan incorporated by reference does not contain all of the
required elements of the SWPPP, the operator must develop the missing elements
and include them in the SWPPP.
f. SWPPP requirements for discharges to impaired waters,
surface waters located within a TMDL watershed, and exceptional waters. The
SWPPP shall:
(1) Identify impaired water(s), associated
impairment(s), TMDL name(s), TMDL pollutant(s) of concern, and exceptional
waters when applicable; and
(2) Provide clear direction that:
(a) Permanent or temporary soil stabilization shall be
applied to denuded areas within seven days after final grade is reached on any
portion of the site, when applicable;
(b) Nutrients shall be applied in accordance with
manufacturer's recommendations and shall not be applied during wet weather
events when applicable; and
(c) A modified inspection schedule shall be implemented,
when applicable.
g. Qualified personnel. The name, phone number, and
qualifications of the qualified personnel conducting inspections required by
this permit.
h. Delegation of authority. The individuals or positions
with delegated authority, in accordance with Section III K, to sign inspection
reports or modify the SWPPP.
i. SWPPP signature. The SWPPP shall be signed and dated
in accordance with Section III K. ]
3. The SWPPP requirements of this general permit may be
fulfilled by incorporating by reference other state or local plans such as (i)
an erosion and sediment control (ESC) plan, (ii) an agreement in lieu of a plan
as defined in 9VAC25-840-10, (iii) a stormwater management plan, (iv) a spill
prevention control and countermeasure (SPCC) plan developed for the site under
§ 311 of the federal Clean Water Act or (v) best management practices
(BMP) programs otherwise required for the facility provided that the
incorporated plan meets or exceeds the SWPPP requirements of Section II D. If
an erosion and sediment control plan for the land-disturbing activity is being
incorporated by reference, the referenced plan must be approved by the VESCP
authority of the locality in which the construction activity is to occur prior
to the commencement of land disturbance.
4. All plans incorporated by reference into the SWPPP become
enforceable under this state permit. If a plan incorporated by reference does
not contain all of the required elements of the SWPPP of Section II D, the
operator must develop the missing elements and include them in the required
SWPPP.
5. Once a definable area has been finally stabilized, the
operator may mark this on the SWPPP and no further SWPPP or inspection
requirements apply to that portion of the site (e.g., earth-disturbing
activities around one of three buildings in a complex are done and the area is
finally stabilized; one mile of a roadway or pipeline project is done and
finally stabilized, etc.).
6. The SWPPP shall identify all properties that are no
longer under the control of the operator and the dates on which the operator no
longer had control over each property.
7. The operator must implement the SWPPP as written and
updated in accordance with Section II C from commencement of construction
activity until final stabilization is complete.
[ 1. General information.
a. A signed copy of the registration statement for coverage under the general VPDES permit for discharges of stormwater from construction activities;
b. Upon receipt, a copy of the notice of coverage under the general VPDES permit for discharges of stormwater from construction activities (i.e., notice of coverage letter);
c. Upon receipt, a copy of the general VPDES permit for discharges of stormwater from construction activities;
d. A narrative description of the nature of the construction activity, including the function of the project (e.g., low density residential, shopping mall, highway, etc.);
e. A legible site plan identifying:
(1) Directions of stormwater flow and approximate slopes anticipated after major grading activities;
(2) Limits of land disturbance including steep slopes and natural buffers around surface waters that will not be disturbed;
(3) Locations of major structural and nonstructural control measures, including sediment basins and traps, perimeter dikes, sediment barriers, and other measures intended to filter, settle, or similarly treat sediment, that will be installed between disturbed areas and the undisturbed vegetated areas in order to increase sediment removal and maximize stormwater infiltration;
(4) Locations of surface waters;
(5) Locations where concentrated stormwater is discharged;
(6) Locations of support activities, when applicable and when required by the VSMP authority, including but not limited to (i) areas where equipment and vehicle washing, wheel wash water, and other wash water is to occur; (ii) storage areas for chemicals such as acids, fuels, fertilizers, and other lawn care chemicals; (iii) concrete wash out areas; (iv) vehicle fueling and maintenance areas; (v) sanitary waste facilities, including those temporarily placed on the construction site; and (vi) construction waste storage; and
(7) When applicable, the location of the on-site rain gauge or the methodology established in consultation with the VSMP authority used to identify measurable storm events for inspection purposes.
2. Erosion and sediment control plan.
a. An erosion and sediment control plan approved by the VESCP authority as authorized under the Erosion and Sediment Control Regulations (9VAC25-840), an "agreement in lieu of a plan" as defined in 9VAC25-840-10 from the VESCP authority, or an erosion and sediment control plan prepared in accordance with annual standards and specifications approved by the department. Any operator proposing a new stormwater discharge from construction activities that is not required to obtain erosion and sediment control plan approval from a VESCP authority or does not adopt department-approved annual standards and specifications shall submit the erosion and sediment control plan to the department for review and approval.
b. All erosion and sediment control plans shall include a statement describing the maintenance responsibilities required for the erosion and sediment controls used.
c. A properly implemented approved erosion and sediment control plan, "agreement in lieu of a plan," or erosion and sediment control plan prepared in accordance with department-approved annual standards and specifications, that adequately:
(1) Controls the volume and velocity of stormwater runoff within the site to minimize soil erosion;
(2) Controls stormwater discharges, including peak flow rates and total stormwater volume, to minimize erosion at outlets and to minimize downstream channel and stream bank erosion;
(3) Minimizes the amount of soil exposed during the construction activity;
(4) Minimizes the disturbance of steep slopes;
(5) Minimizes sediment discharges from the site in a manner that addresses (i) the amount, frequency, intensity, and duration of precipitation; (ii) the nature of resulting stormwater runoff; and (iii) soil characteristics, including the range of soil particle sizes present on the site;
(6) Provides and maintains natural buffers around surface waters, directs stormwater to vegetated areas to increase sediment removal, and maximizes stormwater infiltration, unless infeasible;
(7) Minimizes soil compaction and, unless infeasible, preserves topsoil;
(8) Ensures that stabilization of disturbed areas will be initiated immediately whenever any clearing, grading, excavating, or other land-disturbing activities have permanently ceased on any portion of the site, or temporarily ceased on any portion of the site and will not resume for a period exceeding 14 days; and
(9) Utilizes outlet structures that withdraw stormwater from the surface (i.e., above the permanent pool or wet storage water surface elevation), unless infeasible, when discharging from sediment basins or sediment traps.
3. Stormwater management plan.
a. New construction activities. A stormwater management plan approved by the VSMP authority as authorized under the Virginia Stormwater Management Program (VSMP) Regulation (9VAC25-870), or a stormwater management plan prepared in accordance with annual standards and specifications approved by the department. Any operator proposing a new stormwater discharge from construction activities that is not required to obtain stormwater management plan approval from a VSMP authority or does not adopt department-approved annual standards and specifications shall submit the stormwater management plan to the department for review and approval.
b. Existing construction activities. Any operator that was authorized to discharge under the general permit issued in 2009, and that intends to continue coverage under this general permit, shall ensure compliance with the requirements of 9VAC25-870-93 through 9VAC25-870-99 of the VSMP Regulation, including but not limited to the water quality and quantity requirements. The SWPPP shall include a description of, and all necessary calculations supporting, all post-construction stormwater management measures that will be installed prior to the completion of the construction process to control pollutants in stormwater discharges after construction operations have been completed. Structural measures should be placed on upland soils to the degree possible. Such measures must be designed and installed in accordance with applicable VESCP authority, VSMP authority, state, and federal requirements, and any necessary permits must be obtained.
4. Pollution prevention plan. A pollution prevention plan that addresses potential pollutant-generating activities that may reasonably be expected to affect the quality of stormwater discharges from the construction activity, including any support activity. The pollution prevention plan shall:
a. Identify the potential pollutant-generating activities and the pollutant that is expected to be exposed to stormwater;
b. Describe the location where the potential pollutant-generating activities will occur, or if identified on the site plan, reference the site plan;
c. Identify all nonstormwater discharges, as authorized in Part I E of this general permit, that are or will be commingled with stormwater discharges from the construction activity, including any applicable support activity;
d. Identify the person responsible for implementing the pollution prevention practice or practices for each pollutant-generating activity (if other than the person listed as the qualified personnel);
e. Describe the pollution prevention practices and procedures that will be implemented to:
(1) Prevent and respond to leaks, spills, and other releases including (i) procedures for expeditiously stopping, containing, and cleaning up spills, leaks, and other releases; and (ii) procedures for reporting leaks, spills, and other releases in accordance with Part III G;
(2) Prevent the discharge of spilled and leaked fuels and chemicals from vehicle fueling and maintenance activities (e.g., providing secondary containment such as spill berms, decks, spill containment pallets, providing cover where appropriate, and having spill kits readily available);
(3) Prevent the discharge of soaps, solvents, detergents, and wash water from construction materials, including the clean-up of stucco, paint, form release oils, and curing compounds (e.g., providing (i) cover (e.g., plastic sheeting or temporary roofs) to prevent contact with stormwater; (ii) collection and proper disposal in a manner to prevent contact with stormwater; and (iii) a similarly effective means designed to prevent discharge of these pollutants);
(4) Minimize the discharge of pollutants from vehicle and equipment washing, wheel wash water, and other types of washing (e.g., locating activities away from surface waters and stormwater inlets or conveyance and directing wash waters to sediment basins or traps, using filtration devices such as filter bags or sand filters, or using similarly effective controls);
(5) Direct concrete wash water into a leak-proof container or leak-proof settling basin. The container or basin shall be designed so that no overflows can occur due to inadequate sizing or precipitation. Hardened concrete wastes shall be removed and disposed of in a manner consistent with the handling of other construction wastes. Liquid concrete wastes shall be removed and disposed of in a manner consistent with the handling of other construction wash waters and shall not be discharged to surface waters;
(6) Minimize the discharge of pollutants from storage, handling, and disposal of construction products, materials, and wastes including (i) building products such as asphalt sealants, copper flashing, roofing materials, adhesives, and concrete admixtures; (ii) pesticides, herbicides, insecticides, fertilizers, and landscape materials; and (iii) construction and domestic wastes such as packaging materials, scrap construction materials, masonry products, timber, pipe and electrical cuttings, plastics, styrofoam, concrete, and other trash or building materials;
(7) Prevent the discharge of fuels, oils, and other petroleum products, hazardous or toxic wastes, and sanitary wastes; and
(8) Address any other discharge from the potential pollutant-generating activities not addressed above; and
f. Describe procedures for providing pollution prevention awareness of all applicable wastes, including any wash water, disposal practices, and applicable disposal locations of such wastes, to personnel in order to comply with the conditions of this general permit. The operator shall implement the procedures described in the SWPPP.
5. SWPPP requirements for discharges to impaired waters, surface waters with an applicable TMDL wasteload allocation established and approved prior to the term of this general permit, and exceptional waters. The SWPPP shall:
a. Identify the impaired water(s), approved TMDL(s), pollutant(s) of concern, and exceptional waters identified in 9VAC25-260-30 A 3 c, when applicable;
b. Provide clear direction that:
(1) Permanent or temporary soil stabilization shall be applied to denuded areas within seven days after final grade is reached on any portion of the site;
(2) Nutrients shall be applied in accordance with manufacturer's recommendations or an approved nutrient management plan and shall not be applied during rainfall events; and
(3) A modified inspection schedule shall be implemented in accordance with Part I B 4 or Part I B 5.
6. Qualified personnel. The name, phone number, and qualifications of the qualified personnel conducting inspections required by this general permit.
7. Delegation of authority. The individuals or positions with delegated authority, in accordance with Part III K, to sign inspection reports or modify the SWPPP.
8. SWPPP signature. The SWPPP shall be signed and dated in accordance with Part III K. ]
B. Signature, SWPPP review and making SWPPPs available.
1. The SWPPP shall be signed in accordance with Section III
K.
2. The SWPPP shall be retained, along with a copy of this
state permit, registration statement, and state permit coverage letter from the
department, at the construction site or other location easily accessible during
normal business hours from the date of commencement of construction activity to
the date of final stabilization. Operators with day-to-day operational control
over SWPPP implementation shall have a copy of the SWPPP available at a central
location on-site for the use of all operators and those identified as having
responsibilities under the SWPPP whenever they are on the construction site.
The SWPPP must be made available, in its entirety, to the department, the VSMP
authority, and the operator of a municipal separate storm sewer system
receiving discharges from the site for review at the time of an on-site
inspection. If an on-site location is unavailable to store the SWPPP when no
personnel are present, notice of the SWPPP's location must be posted near the
main entrance at the construction site.
3. The operator shall make SWPPPs and all updates available
upon request to the department; the VSMP authority; EPA; a state or local
agency approving erosion and sediment control plans, grading plans, or
stormwater management plans; local government officials; or the operator of a
municipal separate storm sewer system receiving discharges from the site.
4. A sign or other notice must be posted conspicuously near
the main entrance of the construction site. The sign or other notice must
contain the following information:
a. A copy of the state permit coverage letter than includes
the registration number for the construction activity; and
b. The Internet address at which a copy of the SWPPP may be
found or the location of a hard copy of the SWPPP and name and telephone number
of a contact person for scheduling viewing times.
For linear projects, the sign or other notice must be posted
at a publicly accessible location near an active part of the construction
project (e.g., where a pipeline project crosses a public road).
5. For discharges that commence on or after July 1, 2009,
that have not previously held coverage under a state or VPDES permit, the
operator shall make the SWPPP available to the public for review. A copy of the
SWPPP for each site shall be made available on the Internet or in hard copy.
The website address or contact person for access to the SWPPP shall be posted
on the sign required by subdivision B 4 of this section. If not provided
electronically, access to the SWPPP may be arranged upon request at a time and
at a publicly accessible location convenient to the operator or his designee
but shall be no less than once per month and shall be during normal business
hours. If a reproduced copy of the SWPPP is provided to the requestor, the
requestor shall be responsible for the costs of reproduction. Information
excluded from disclosure under applicable law shall not be required to be
released. Information not required to be contained within the SWPPP by this state
permit is not required to be released.
C. Maintaining an updated SWPPP.
1. The operator shall amend the SWPPP whenever there is a
change in design, construction, operation, or maintenance that has a
significant effect on the discharge of pollutants to state waters and that has
not been previously addressed in the SWPPP.
2. The SWPPP must be amended if during inspections or
investigations by the operator's qualified personnel, or by VESCP authority,
VSMP authority, state or federal officials, it is determined that the existing
control measures are ineffective in minimizing pollutants in stormwater
discharges from the construction site. Revisions to the SWPPP shall include
additional or modified control measures designed to correct problems
identified. If approval by a VSMP authority is necessary for the control
measure, revisions to the SWPPP shall be completed within seven calendar days
of approval. Implementation of these additional or modified control measures
must be accomplished as described in Section II D 3 b.
3. Revisions to the SWPPP must be dated and signed in
accordance with Section III K 2, but are not required to be certified in
accordance with Section III K 4.
4. The SWPPP must clearly identify the contractor(s) or
subcontractor(s) that will implement and maintain each measure identified in
the SWPPP. The SWPPP shall be revised to identify any new contractor that will
implement a measure.
D. Stormwater pollution prevention plan contents. The SWPPP
shall include the registration statement, this state permit, and the following
items:
1. Site and activity description. Each SWPPP shall provide
the following information:
a. A narrative description of the nature of the
construction activity, including the function of the project (e.g., low density
residential, shopping mall, highway, etc.);
b. The intended sequence and timing of activities that
disturb soils at the site (e.g., grubbing, excavation, grading, utilities and
infrastructure installation);
c. A record of the dates when major grading activities
occur, when construction activities temporarily or permanently cease on a
portion of the site, and when stabilization measures are initiated;
d. Estimates of the total area expected to be disturbed by
excavation, grading, or other construction activities including off-site borrow
and fill areas;
e. A description of any other potential pollutant sources,
such as vehicle fueling, storage of fertilizers or chemicals, sanitary waste
facilities, etc.;
f. Identification of the nearest receiving waters at or
near the construction site that will receive discharges from disturbed areas of
the project;
g. The location and description of any discharge associated
with industrial activity other than construction at the site. This includes
stormwater discharges from dedicated asphalt plants and dedicated concrete
plants that are covered by this state permit;
h. A legible general location map (e.g., USGS quadrangle map,
a portion of a city or county map, or other map) with sufficient detail to
identify the location of the construction activity and surface waters within
one mile of the construction activity; and
i. A legible site map identifying:
(1) Directions of stormwater flow and approximate slopes
anticipated after major grading activities;
(2) Areas of soil disturbance and areas of the site which
will not be disturbed;
(3) Locations of major structural and nonstructural control
measures identified in the SWPPP, including those that will be permanent after
construction activities have been completed;
(4) Locations where stabilization practices are expected to
occur;
(5) Locations of surface waters;
(6) Locations where concentrated stormwater discharges;
(7) Locations of off-site material, waste, borrow or
equipment storage areas covered by the SWPPP;
(8) Locations of other potential pollutant sources, such as
vehicle fueling, storage of chemicals, concrete wash-out areas, sanitary waste
facilities, including those temporarily placed on the construction site, etc.;
and
(9) Areas where final stabilization has been accomplished.
2. Controls to minimize pollutants. The SWPPP shall include
a description of all control measures that will be implemented as part of the
construction activity to minimize pollutants in stormwater discharges. For each
major activity identified in the project description, the SWPPP shall clearly
describe appropriate control measures, the general sequencing during the
construction process in which the control measures will be implemented, and
which operator is responsible for the control measure's implementation.
a. Erosion and sediment controls.
(1) An erosion and sediment control plan or an agreement in
lieu of a plan shall be approved by the appropriate VESCP authority for the
land-disturbing activity in accordance with the Virginia Erosion and Sediment
Control Law and regulations (9VAC25-840). Where applicable, a plan shall be
developed in accordance with board-approved annual general erosion and sediment
control specifications.
(2) All control measures required by the plan shall be
designed, installed, and maintained in accordance with good engineering
practices and the minimum standards of the Virginia Erosion and Sediment
Control Law and regulations (9VAC25-840).
b. Management practices.
(1) Plans should ensure that existing vegetation is
preserved where possible and that disturbed portions of the site are
stabilized.
(2) All control measures must be properly selected,
installed, and maintained in accordance with good engineering practices and,
where applicable, manufacturer specifications. If periodic inspections or other
information indicates a control has been used inappropriately or incorrectly,
the operator must replace or modify the control for site situations as soon as
practicable and update the SWPPP in accordance with Section II C.
(3) If sediment escapes the construction site, off-site
accumulations of sediment must be removed as soon as practicable to minimize
off-site impacts. If approval by a VESCP authority is necessary, control
measures shall be implemented to minimize pollutants in stormwater discharges
until such approvals can be obtained.
(4) Construction debris and construction chemicals exposed
to stormwater shall be prevented from becoming a pollutant source in stormwater
discharges.
(5) Litter exposed to stormwater shall be prevented from
becoming a pollutant source in stormwater discharges and the construction site
shall be policed daily to control litter.
c. Stormwater management.
(1) The operator shall ensure compliance with the
requirements of 9VAC25-880-80 through 9VAC25-880-90 of the General Permit for
Discharges of Stormwater from Construction Activities regulations, including
but not limited to water quality and quantity requirements. The SWPPP shall
include a description of, and all necessary calculations supporting, all
post-construction stormwater management measures that will be installed prior
to the completion of the construction process to control pollutants in
stormwater discharges after construction operations have been completed.
Structural measures should be placed on upland soils to the degree possible.
Such measures must be designed and installed in accordance with applicable
VESCP authority, VSMP authority, state, and federal requirements, and any
necessary permits must be obtained.
(2) Control measures contained in Part II (9VAC25-870-40 et
seq.) of the Virginia Stormwater Management Regulations, 9VAC25-880-84, or on
the Virginia BMP Clearinghouse Website may be utilized. Innovative or alternate
control measures may be allowed by the department provided such measures
effectively address water quality and quantity in accordance with the
requirements of 9VAC25-880-80 through 9VAC25-880-90 and are not restricted by
the locality in accordance with § 62.1-44.15:33 of the Code of Virginia.
(3) Where applicable, the SWPPP shall contain additional
information related to participation in a regional stormwater management plan,
including:
(a) Type of regional facility or facilities to which the
site contributes;
(b) Geographic location of any regional facility to which
the site contributes (county or city and Hydrologic Unit Code);
(c) Geographic location of the site (county or city and Hydrologic
Unit Code). Latitude and longitude may additionally be included if available;
and
(d) Number of acres treated by a regional facility.
(4) Where applicable, the SWPPP shall contain additional
information related to nutrient offsets to be acquired in accordance with §
62.1-44.15:35 of the Code of Virginia, including:
(a) Name of the broker from which offsets will be acquired;
(b) Geographic location (county or city and Hydrologic Unit
Code) of the broker's offset generating facility;
(c) Number of nutrient offsets to be acquired (lbs. per
acre per year); and
(d) Nutrient reductions to be achieved on site (lbs. per
acre per year).
(5) Outflows from a stormwater management facility or
stormwater conveyance system shall be discharged to an adequate channel as
defined in the Virginia Erosion and Sediment Control Regulations (9VAC25-840).
In addition, all control measures shall be employed in a manner that minimizes
impacts on the physical, chemical and biological integrity of rivers, streams,
and other state waters, is protective of water quality standards, and is
consistent with Section II D 6 and D 7 and other applicable provisions of this
state permit.
d. Other controls.
(1) The SWPPP shall describe measures to prevent the
discharge of solid materials, including building materials, garbage, and debris
to state waters, except as authorized by a Clean Water Act § 404 permit.
(2) The SWPPP shall describe control measures used to
comply with applicable state or local waste disposal, sanitary sewer or septic
system regulations.
(3) The SWPPP shall include a description of construction
and waste materials expected to be stored on-site with updates as appropriate.
The SWPPP shall also include a description of controls including storage
practices, to minimize exposure of the materials to stormwater, and for spill
prevention and response.
(4) The SWPPP shall include a description of pollutant
sources from off-site areas (including stormwater discharges from dedicated
asphalt plants and dedicated concrete plants), and a description of control
measures that will be implemented at those sites to minimize pollutant
discharges.
e. Applicable state or local programs. The control measures
implemented at the site shall be consistent with all applicable federal, state,
or VESCP or VSMP authority requirements for erosion and sediment control and
stormwater management. The SWPPP shall be updated as necessary to reflect any
revisions to applicable federal, state or VESCP or VSMP authority requirements
that affect the control measures implemented at the site.
3. Maintenance of controls.
a. All control measures must be properly maintained in
effective operating condition in accordance with good engineering practices
and, where applicable, manufacturer specifications. If site inspections
required by Section II D 4 identify control measures that are not operating
effectively, maintenance shall be performed as soon as practicable to maintain
the continued effectiveness of stormwater controls.
b. If site inspections required by Section II D 4 identify
existing control measures that need to be modified or if additional control
measures are necessary for any reason, implementation shall be completed before
the next anticipated storm event. If implementation before the next anticipated
storm event is impracticable, the situation shall be documented in the SWPPP
and alternative control measures shall be implemented as soon as practicable.
4. Inspections. The name and phone number of qualified
personnel conducting inspections shall be included in the SWPPP.
a. Inspections shall be conducted (i) at least every seven
calendar days or (ii) at least once every 14 calendar days and within 48 hours
following any runoff producing storm event. Where areas have been temporarily
stabilized or runoff is unlikely due to winter conditions (e.g., the site is
covered with snow or ice, or frozen ground exists) such inspections shall be
conducted at least once every month.
b. Inspections must include all areas of the site disturbed
by construction activity, off-site areas covered by the state permit, and areas
used for storage of materials that are exposed to precipitation, but does not
need to include areas identified pursuant to Section II A 5. Inspectors must
look for evidence of, or the potential for, pollutants entering a stormwater
conveyance system. Control measures identified in the SWPPP shall be inspected
for proper installation, maintenance, and operation. Discharge locations, where
accessible, shall be inspected to ascertain whether control measures are
effective in minimizing impacts to receiving waters. Where discharge locations
are inaccessible, nearby downstream locations shall be inspected to the extent
that such inspections are practicable. Locations where vehicles enter or exit
the site shall be inspected for evidence of off-site sediment tracking.
c. Utility line installation, pipeline construction, and
other examples of long, narrow, linear construction activities may limit the
access of inspection personnel to the areas described in Section II D 4 b.
Inspection of these areas could require that vehicles compromise temporarily or
even permanently stabilized areas, cause additional disturbance of soils, and
increase the potential for erosion. In these circumstances, controls must be inspected
on the same frequencies as other construction projects, but representative
inspections may be performed. For representative inspections, personnel must
inspect controls along the construction site for 0.25 miles above and below
each access point where a roadway, undisturbed right-of-way, or other similar
feature intersects the construction site and allows access to the areas
described above. The conditions of the controls along each inspected 0.25-mile
segment may be considered as representative of the condition of controls along
that reach extending from the end of the 0.25-mile segment to either the end of
the next 0.25-mile segment, or to the end of the project, whichever occurs
first. Inspection locations must be listed in the report required by Section II
D 4 d.
d. A report summarizing the scope of the inspection, names
and qualifications of personnel making the inspection, the dates of the
inspection, major observations relating to the implementation of the SWPPP, and
actions taken in accordance with Section II D 4 d of the state permit shall be
made and retained as part of the SWPPP in accordance with Section III B of this
state permit. Major observations should include:
(1) The location(s) of discharges of sediment or other
pollutants from the site;
(2) Location(s) of control measures that need to be
maintained;
(3) Location(s) of control measures that failed to operate
as designed or proved inadequate for a particular location;
(4) Location(s) where additional control measures are needed
that did not exist at the time of inspection;
(5) Corrective action required including any changes to the
SWPPP that are necessary and implementation dates;
(6) An estimate of the amount of rainfall at the
construction site (in inches) from the runoff producing storm event requiring
the inspection, or if inspecting on a seven-day schedule, the amount of
rainfall (in inches) since the previous inspection; and
(7) Weather information and a description of any discharges
occurring at the time of inspection.
A record of each inspection and of any actions taken in
accordance with Section II must be retained by the operator as part of the
SWPPP for at least three years from the date that state permit coverage expires
or is terminated. The inspection reports shall identify any incidents of
noncompliance. Where a report does not identify any incidents of noncompliance,
the report shall contain a certification that the facility is in compliance
with the SWPPP and this state permit. The report shall be signed in accordance
with Section III K of this state permit.
5. Nonstormwater discharge management. The SWPPP shall
identify all allowable sources of nonstormwater discharges listed in Section I
D 2 of this state permit that are combined with stormwater discharges from the
construction activity at the site, except for flows from firefighting
activities. The SWPPP shall identify and require the implementation of
appropriate control measures for the nonstormwater components of the discharge.
6. Total maximum daily loads. An approved total maximum
daily load (TMDL) may include a wasteload allocation to the regulated
construction activity that identifies the pollutant for which stormwater
control measures are necessary for the surface waters to meet water quality
standards. The pollutant identified in a wasteload allocation as of the
effective date of this state permit must be specified in the SWPPP. The SWPPP
shall include strategies and control measures to ensure consistency with the
assumptions and requirements of the TMDL WLA that apply to the operator's
discharge. In a situation where a TMDL has specified a general wasteload
allocation applicable to construction stormwater discharges, but no specific
requirements for construction sites have been identified in the TMDL, the
operator shall consult with the state or federal TMDL authority to confirm that
meeting state permit requirements will be consistent with the approved TMDL. If
the TMDL specifically precludes such discharges, the operator is not eligible
for coverage under the general permit.
7. Impaired waters. In accordance with Section I H, control
measures shall be protective of water quality standards for impaired waters
identified as having impairments for pollutants that may be discharged from the
construction activity in the 2008 § 305(b)/303(d) Water Quality Assessment
Integrated Report.
B. SWPPP [ amendments, ] modification,
[ and ] updates [ , and records ].
1. The operator shall amend the SWPPP whenever there is a change in [ the ] design, construction, operation, or maintenance that has a significant effect on the discharge of pollutants to surface waters and that has not been previously addressed in the SWPPP.
2. The SWPPP must be amended if, during inspections or
investigations by the operator's qualified personnel, or by local, state, or
federal officials, it is determined that the existing control measures are
ineffective in minimizing pollutants in discharges from the construction
[ site activity ]. Revisions to the SWPPP shall
include additional or modified control measures designed and implemented to
correct problems identified. If approval by the VESCP authority, VSMP
authority, or [ the ] department is necessary
for the control measure, revisions to the SWPPP shall be completed no later
than seven [ calendar ] days following approval.
Implementation of these additional or modified control measures must be
accomplished as described in [ Section Part ]
II G.
[ 3. Revisions to the SWPPP shall be signed and
dated in accordance with Section III K 2 but are not required to be certified
in accordance with Section III K 4.
4. 3. ] The SWPPP must clearly
identify the contractor(s) that will implement and maintain each control
measure identified in the SWPPP. The SWPPP shall be [ revised
amended ] to identify any new contractor that will implement and
maintain a control measure.
[ 5. 4. ] The operator shall
update the SWPPP no later than seven days following any [ modifications
modification ] to its implementation. All modifications or
[ changes updates ] to the SWPPP shall be
noted [ . Updates and modifications shall be signed and dated in
accordance with Section III K ] and shall include [ the
following items ]:
a. A record of dates when:
(1) Major grading activities occur;
(2) Construction activities temporarily or permanently cease on a portion of the site; and
(3) Stabilization measures are initiated [ .; ]
b. Documentation of replaced or modified controls where periodic inspections or other information have indicated that the controls have been used inappropriately or incorrectly and where modified as soon as possible;
c. Areas that have reached final stabilization and where no further SWPPP or inspection requirements apply;
d. All properties that are no longer under the legal control of the operator and the dates on which the operator no longer had legal control over each property;
e. The date of any prohibited discharges, the discharge volume released, and what actions were taken to minimize the impact of the release;
f. Measures taken to prevent the reoccurrence of any prohibited discharge; [ and ]
g. Measures taken to address any evidence identified as a
result of an inspection required under [ Section Part ]
II F [ ; and.
h. Updates necessary to reflect any revisions to
applicable federal, state, or local requirements that affect the control
measures implemented at the site.
5. Amendments, modifications, or updates to the SWPPP shall be signed in accordance with Part III K. ]
C. Public Notification. Upon commencement of land
disturbance, the operator shall [ maintain and ] post
conspicuously [ a copy of the notice of coverage letter ] near
the main entrance of the construction activity [ : 1. A copy of
the Notice of Coverage letter; 2.. ] For linear
projects, the [ operators operator ] shall
post the [ information notice of coverage letter ]
at a publicly accessible location near an active part of the construction
project (e.g., where a pipeline [ project ] crosses
a public road) [ ; and 3.. ] The operator
shall maintain the posted information until termination of general permit
coverage [ as specified in Part I F ].
D. SWPPP availability.
1. Operators with day-to-day operational control over SWPPP implementation shall have a copy of the SWPPP available at a central location on-site for use by those identified as having responsibilities under the SWPPP whenever they are on the construction site.
2. The operator shall make [ SWPPPs
the SWPPP ] and all [ updates amendments,
modifications, and updates ] available upon request to the
department, the VSMP authority, the EPA, [ the ] VESCP
[ authorities authority ], local government
officials, or the operator of a municipal separate storm sewer system receiving
discharges from the construction activity. If an on-site location is unavailable
to store the SWPPP when no personnel are present, notice of the SWPPP's
location must be posted near the main entrance of the construction site.
[ 3. The operator shall make the SWPPP available for public review in an electronic format or in hard copy. Information for public access to the SWPPP shall be posted and maintained in accordance with Part II C. If not provided electronically, public access to the SWPPP may be arranged upon request at a time and at a publicly accessible location convenient to the operator or his designee but shall be no less than once per month and shall be during normal business hours. Information not required to be contained within the SWPPP by this general permit is not required to be released. ]
E. SWPPP implementation. The operator shall implement the
SWPPP and subsequent [ amendments, modifications, and ] updates
from commencement of [ construction activity land
disturbance ] until [ permit ] termination
[ of general permit coverage as specified in Part I F ].
1. All control measures must be properly maintained in
effective operating condition in accordance with good engineering practices
and, where applicable, manufacturer specifications. If [ a ]
site [ inspections inspection ] required
by [ Section Part ] II F [ identify
identifies a ] control [ measures measure ]
that [ are is ] not operating
effectively, corrective [ action action(s) ]
shall be [ performed completed ] as
soon as practicable, but no later than seven days after discovery [ or
a longer period as established by the VSMP authority ], to maintain
the continued effectiveness of [ stormwater controls
the control measures ].
2. If site inspections required by [ Section
Part ] II F identify [ an ] existing
control [ measures measure ] that
[ need needs ] to be modified or if
[ an ] additional control [ measures
measure is ] necessary for any reason, implementation shall be
completed prior to the next anticipated [ measurable ] storm
event. If implementation prior to the next anticipated [ measurable ]
storm [ even event ] is impracticable,
then [ the situation shall be documented in the SWPPP and ]
alternative control measures shall be implemented as soon as practicable,
but no later than seven days after discovery [ or a longer period
as established by the VSMP authority ].
F. [ SWPPP ] Inspections.
1. Personnel responsible for on-site and off-site inspections. Inspections required by this [ general ] permit shall be conducted by the qualified personnel identified by the operator in the SWPPP. The operator is responsible for insuring that the qualified personnel conduct the inspection.
2. Inspection schedule.
a. Inspections shall be conducted at a frequency of:
(1) At least once every [ seven
five business ] days; or
(2) At least once every [ 14 10
business ] days and no later than 48 hours following [ any
a ] measurable storm event. In the event that a measurable storm
event occurs when there are more than 48 hours between [ normal
working business ] days, the inspection shall be
conducted no later than the next business day.
b. Where areas have been temporarily stabilized or
[ runoff is unlikely due to winter conditions (e.g., the site is
covered with snow or ice, or continuous frozen ground exists)
land-disturbing activities will be suspended due to continuous frozen ground
conditions and stormwater discharges are unlikely ], the inspection
frequency may be reduced to once [ every 30 days per
month. ] If [ unexpected ] weather
conditions (such as above freezing temperatures or rain or snow events) make
discharges likely, the operator shall immediately resume the regular inspection
frequency.
c. Representative inspections may be utilized for utility line installation, pipeline construction, or other similar linear construction activities provided that:
(1) Temporary or permanent [ soil ] stabilization
has been installed and [ where ] vehicle access
may compromise [ the ] temporary or permanent
[ soil ] stabilization and potentially cause additional
[ land ] disturbance [ of soils ]
increasing the potential for erosion;
(2) Inspections occur on the same [ frequencies
frequency ] as other construction [ projects.
Controls activities;
(3) Control measures ] are inspected along the
construction site [ of ] 0.25 miles above and
below each access point [ (i.e., ] where a roadway,
undisturbed right-of-way, or other similar feature intersects the construction
[ site activity ] and [ allows ]
access [ to the areas without compromising does
not compromise ] temporary or permanent [ soil ]
stabilization [ ) ]; and
[ (3) (4) ] Inspection
locations [ shall be listed are provided ] in
the report required by [ Section Part ] II
F.
3. Inspection requirements.
a. As part of the inspection, the qualified personnel shall:
(1) Record the date and time of the inspection and
[ when applicable ] the [ amount of
cumulative rainfall since the last inspection date and rainfall
amount of the last measurable storm event ];
(2) Record the information and a description of any discharges occurring at the time of the inspection;
(3) Record any land-disturbing activities that have occurred outside of the approved erosion and sediment control plan;
(4) Inspect the following for installation in accordance
with the approved erosion and sediment control plan, [ identify
identification of any ] maintenance needs [ , ]
and [ evaluate evaluation of ] effectiveness
in minimizing sediment discharge, including whether the control has been inappropriately
or incorrectly used:
(a) All perimeter erosion and sediment controls, such as silt fence;
(b) Soil stockpiles [ , when applicable, ] and borrow areas for stabilization or sediment trapping measures;
(c) Completed earthen structures, such as dams, dikes, ditches, and diversions for stabilization;
(d) Cut and fill slopes;
(e) Sediment basins and traps, sediment barriers, and other
measures installed to control sediment discharge from [ concentrated ]
stormwater;
(f) Temporary or permanent channel, flume, or other slope
drain structures installed to convey concentrated runoff [ flowing ]
down cut and fill slopes;
(g) Storm inlets that have been made operational to ensure that sediment laden stormwater does not enter without first being filtered or similarly treated; and
(h) Construction vehicle access routes that intersect or
access paved roads for minimizing sediment tracking [ .; ]
(5) Inspect areas that have reached final grade or that will remain dormant for more than 14 days for initiation of stabilization activities;
(6) Inspect areas that have reached final grade or that will remain dormant for more than 14 days for completion of stabilization activities within seven days of reaching grade or stopping work;
(7) Inspect for evidence that the [ approved ]
erosion and sediment control plan [ , "agreement in lieu of
a plan," or erosion and sediment control plan prepared in accordance with
department-approved annual standards and specifications ] has not
been properly implemented [ and is not meeting the requirements
of Section II A 2 b (4). Evidence. This ] includes but
is not limited to:
(a) [ Evidence of concentrated
Concentrated ] flows of stormwater [ in conveyances ]
such as rills, rivulets or channels that [ cause erosion when
such flows are have ] not [ been ] filtered,
settled [ , ] or similarly treated prior to discharge
[ , or evidence thereof ];
(b) Sediment laden or turbid flows of stormwater that
[ are have ] not [ been ]
filtered or settled to remove sediments prior to discharge;
(c) [ Deposits of sediment
Sediment deposition ] in areas that drain to unprotected stormwater
inlets or [ to ] catch basins that discharge to
surface waters. Inlets and catch basins with failing sediments controls due to
improper installation, lack of maintenance, or inadequate design are considered
unprotected;
(d) [ Deposits of sediment from the
construction activity Sediment deposition ] on any property
(including public and private streets) outside of the construction activity
covered by this [ general ] permit;
(e) [ Portions of the site where required
Required ] stabilization has not been initiated or completed
[ on portions of the site ];
(f) Sediment basins without [ a dewatering
device allowing for discharge from below the designed permanent pool elevation
adequate wet or dry storage volume or sediment basins that allow the discharge
of stormwater from below the surface of the wet storage portion of the basin ];
(g) Sediment traps without adequate wet [ and
or ] dry storage [ and without restricted discharge
from the drawdown of dry or sediment traps that allow the discharge
of stormwater from below the surface of the wet ] storage portion
of the trap; and
(h) Land disturbance outside of the [ delineated
approved ] area to be disturbed;
(8) Inspect pollutant generating activities identified in the pollution prevention plan for the proper implementation, maintenance and effectiveness of the procedures and practices;
(9) Identify any pollutant generating activities not identified in the pollution prevention plan; and
(10) Identify and document the presence of any evidence of the discharge of pollutants prohibited by this [ general ] permit.
4. Inspection report. Each inspection [ report ]
shall [ document in a report include the following
items ]:
a. The date and time of the inspection [ and when applicable, the date and rainfall amount of the last measurable storm event ];
b. Summarized findings of the inspection;
c. The location(s) of prohibited discharges;
d. The location(s) of control measures that require maintenance;
e. The location(s) of control measures that failed to operate as designed or proved inadequate [ or inappropriate ] for a particular location;
f. The location(s) where [ any ] evidence
identified under [ Section Part ] II F 3
a (7) exists;
g. The location(s) where [ any ] additional
control [ measures are measure is ] needed
that did not exist at the time of inspection;
h. A list of corrective actions required [ including
(including ] any changes to the SWPPP that are necessary [ to
implement ) ] as a result of the inspection
[ and in order or ] to maintain permit
compliance;
i. Documentation of any corrective actions required from a
previous inspection that have [ yet to be not been ]
implemented; and
j. The date and signature of the qualified personnel and
[ the ] operator or [ the its
duly ] authorized representative.
The inspection report and any actions taken in accordance
with [ Section Part ] II must be retained
by the operator as part of the SWPPP for at least three years from the date
that [ general ] permit coverage expires or is
terminated. The inspection [ reports report ]
shall identify any incidents of noncompliance. Where [ a
an inspection ] report does not identify any incidents of
noncompliance, the report shall contain a certification that the [ facility
construction activity ] is in compliance with the SWPPP and this
[ state general ] permit. The report shall be
signed in accordance with [ Section Part ] III
K of this [ general ] permit.
G. Corrective actions.
1. The operator shall implement the corrective action(s)
identified as a result of an inspection as soon as practicable but no later than
seven days after discovery [ or a longer period as approved by the
VSMP authority ]. If approval [ of a corrective action ]
by a regulatory authority (e.g., VSMP authority, VESCP authority [ ,
or the department ] ) [ of a corrective action ]
is necessary, additional control measures shall be implemented to minimize
pollutants in stormwater discharges until such approvals can be obtained.
2. The operator may be required to remove accumulated
sediment deposits located outside of the construction activity covered by this
[ general ] permit as soon as practicable in order to
minimize environmental impacts. The operator shall notify the [ VSMP
authority and the ] department [ and as
well as ] obtain all applicable federal, state, and local
authorizations, approvals, and permits prior to the removal of sediments
accumulated in surface waters including wetlands.
[ SECTION PART ] III
CONDITIONS APPLICABLE TO ALL [ STATE VPDES ] PERMITS
NOTE: Discharge monitoring is not required for this [ state
general ] permit. If the operator chooses to monitor stormwater
discharges or control measures, the operator must comply with the requirements
of subsections A, B, and C, as appropriate.
A. Monitoring.
1. Samples and measurements taken for the purpose of monitoring shall be representative of the monitoring activity.
2. Monitoring shall be conducted according to procedures
approved under 40 CFR Part 136 or alternative methods approved by the U.S.
Environmental Protection Agency, unless other procedures have been specified in
this [ state general ] permit. [ Analyses
performed according to test procedures approved under 40 CFR Part 136
shall be performed by an environmental laboratory certified under regulations
adopted by the Department of General Services (1VAC30-45 or 1VAC30-46). ]
3. The operator shall periodically calibrate and perform maintenance procedures on all monitoring and analytical instrumentation at intervals that will ensure accuracy of measurements.
B. Records.
1. Monitoring records and reports shall include:
a. The date, exact place, and time of sampling or measurements;
b. The individual(s) who performed the sampling or measurements;
c. The date(s) and time(s) analyses were performed;
d. The individual(s) who performed the analyses;
e. The analytical techniques or methods used; and
f. The results of such analyses.
2. The operator shall retain records of all monitoring
information, including all calibration and maintenance records and all original
strip chart recordings for continuous monitoring instrumentation, copies of all
reports required by this [ state general ] permit, and
records of all data used to complete the registration statement for this
[ state general ] permit, for a period of at least
three years from the date of the sample, measurement, report or request for
coverage. This period of retention shall be extended automatically during the
course of any unresolved litigation regarding the regulated activity or
regarding control standards applicable to the operator, or as requested by the
board.
C. Reporting monitoring results.
1. The operator shall update the SWPPP to include the results
of the monitoring as may be performed in accordance with this [ state
general ] permit, unless another reporting schedule is specified
elsewhere in this [ state general ] permit.
2. Monitoring results shall be reported on a discharge monitoring report (DMR); on forms provided, approved or specified by the department; or in any format provided that the date, location, parameter, method, and result of the monitoring activity are included.
3. If the operator monitors any pollutant specifically
addressed by this [ general ] permit more frequently than
required by this [ state general ] permit using test
procedures approved under 40 CFR Part 136 or using other test procedures
approved by the U.S. Environmental Protection Agency or using procedures
specified in this [ general ] permit, the results of this
monitoring shall be included in the calculation and reporting of the data
submitted in the DMR or reporting form specified by the department.
4. Calculations for all limitations which require averaging of
measurements shall utilize an arithmetic mean unless otherwise specified in
this [ state general ] permit.
D. Duty to provide information. The operator shall furnish,
within a reasonable time, any information which the board, department, or
other VSMP authority may request to determine whether cause exists for
modifying, revoking and reissuing, or terminating this [ state general ]
permit or to determine compliance with this [ state general ]
permit. The board, department, [ EPA, ] or [ other ]
VSMP authority may require the operator to furnish, upon request, such plans,
specifications, and other pertinent information as may be necessary to
determine the effect of the wastes from his discharge on the quality of state
surface waters, or such other information as may be necessary to
accomplish the purposes of the CWA and the Virginia Stormwater Management Act.
The operator shall also furnish to the board, department, EPA, or other
VSMP authority, upon request, copies of records required to be kept by this
[ state general ] permit.
E. Compliance schedule reports. Reports of compliance or
noncompliance with, or any progress reports on, interim and final requirements
contained in any compliance schedule of this [ state general ]
permit shall be submitted no later than 14 days following each schedule date.
F. Unauthorized stormwater discharges. Pursuant to § 62.1-44.5 of the Code of Virginia, except in compliance with a state permit issued by the department, it shall be unlawful to cause a stormwater discharge from a construction activity.
G. Reports of unauthorized discharges. Any operator who
discharges or causes or allows a discharge of sewage, industrial waste, other
wastes or any noxious or deleterious substance or a hazardous substance or oil
in an amount equal to or in excess of a reportable quantity established under
either 40 CFR Part 110, 40 CFR Part 117, 40 CFR Part 302, or § [ 62.1-44.15:19
62.1-44.34:19 ] of the Code of Virginia that occurs during a
24-hour period into or upon state surface waters or who
discharges or causes or allows a discharge that may reasonably be expected to
enter state surface waters, shall notify the Department of
Environmental Quality of the discharge immediately upon discovery of the
discharge, but in no case later than within 24 hours after said discovery. A
written report of the unauthorized discharge shall be submitted to the
department and the VSMP authority within five days of discovery of the
discharge. The written report shall contain:
1. A description of the nature and location of the discharge;
2. The cause of the discharge;
3. The date on which the discharge occurred;
4. The length of time that the discharge continued;
5. The volume of the discharge;
6. If the discharge is continuing, how long it is expected to continue;
7. If the discharge is continuing, what the expected total volume of the discharge will be; and
8. Any steps planned or taken to reduce, eliminate and prevent
a recurrence of the present discharge or any future discharges not authorized
by this [ state general ] permit.
Discharges reportable to the department and the VSMP authority under the immediate reporting requirements of other regulations are exempted from this requirement.
H. Reports of unusual or extraordinary discharges. If any
unusual or extraordinary discharge including a "bypass" or
"upset", as defined herein, should occur from a facility and the
discharge enters or could be expected to enter state surface
waters, the operator shall promptly notify, in no case later than within 24
hours, the department and the VSMP authority by telephone after the discovery of
the discharge. This notification shall provide all available details of the
incident, including any adverse effects on aquatic life and the known number of
fish killed. The operator shall reduce the report to writing and shall submit
it to the department and the VSMP authority within five days of discovery of
the discharge in accordance with [ Section Part ] III I
2. Unusual and extraordinary discharges include but are not limited to any
discharge resulting from:
1. Unusual spillage of materials resulting directly or indirectly from processing operations;
2. Breakdown of processing or accessory equipment;
3. Failure or taking out of service of some or all of the facilities; and
4. Flooding or other acts of nature.
I. Reports of noncompliance. The operator shall report any
noncompliance which may adversely affect state surface waters or
may endanger public health.
1. An oral report to the department and the VSMP authority shall be provided within 24 hours from the time the operator becomes aware of the circumstances. The following shall be included as information that shall be reported within 24 hours under this subdivision:
a. Any unanticipated bypass; and
b. Any upset that causes a discharge to state surface
waters.
2. A written report shall be submitted within five days and shall contain:
a. A description of the noncompliance and its cause;
b. The period of noncompliance, including exact dates and times, and if the noncompliance has not been corrected, the anticipated time it is expected to continue; and
c. Steps taken or planned to reduce, eliminate, and prevent reoccurrence of the noncompliance.
The department may waive the written report on a case-by-case
basis for reports of noncompliance under [ Section Part ]
III I if the oral report has been received within 24 hours and no adverse
impact on state surface waters has been reported.
3. The operator shall report all instances of noncompliance not
reported under [ Section Part ] III I 1 or 2 in writing
as part of the SWPPP. The reports shall contain the information listed in
[ Section Part ] III I 2.
NOTE: The reports required in [ Section Part ]
III G, H and I shall be made to the department and the VSMP authority. Reports
may be made by telephone, email, or by fax. For reports outside normal working
hours, leaving a recorded message shall fulfill the immediate reporting
requirement. For emergencies, the Virginia Department of Emergency Management
maintains a 24-hour telephone service at 1-800-468-8892.
4. Where the operator becomes aware of a failure to submit any relevant facts, or submittal of incorrect information in any report, including a registration statement, to the department or the VSMP authority, the operator shall promptly submit such facts or correct information.
J. Notice of planned changes.
1. The operator shall give notice to the department and the VSMP authority as soon as possible of any planned physical alterations or additions to the permitted facility or activity. Notice is required only when:
a. The operator plans an alteration or addition to any building, structure, facility, or installation that may meet one of the criteria for determining whether a facility is a new source in 9VAC25-870-420;
b. The operator plans an alteration or addition that would
significantly change the nature or increase the quantity of pollutants
discharged. This notification applies to pollutants that are not subject to
effluent limitations in this [ state general ] permit;
or
2. The operator shall give advance notice to the department and VSMP authority of any planned changes in the permitted facility or activity, which may result in noncompliance with state permit requirements.
K. Signatory requirements.
1. Registration statement. All registration statements shall be signed as follows:
a. For a corporation: by a responsible corporate officer. For the purpose of this chapter, a responsible corporate officer means: (i) a president, secretary, treasurer, or vice-president of the corporation in charge of a principal business function, or any other person who performs similar policy-making or decision-making functions for the corporation; or (ii) the manager of one or more manufacturing, production, or operating facilities, provided the manager is authorized to make management decisions that govern the operation of the regulated facility including having the explicit or implicit duty of making major capital investment recommendations, and initiating and directing other comprehensive measures to assure long-term compliance with environmental laws and regulations; the manager can ensure that the necessary systems are established or actions taken to gather complete and accurate information for state permit application requirements; and where authority to sign documents has been assigned or delegated to the manager in accordance with corporate procedures;
b. For a partnership or sole proprietorship: by a general partner or the proprietor, respectively; or
c. For a municipality, state, federal, or other public agency: by either a principal executive officer or ranking elected official. For purposes of this chapter, a principal executive officer of a public agency includes: (i) the chief executive officer of the agency or (ii) a senior executive officer having responsibility for the overall operations of a principal geographic unit of the agency.
2. Reports, etc. All reports required by [ state
permits this general permit ], including SWPPPs, and other
information requested by the board or the department shall be signed by a
person described in [ Section Part ] III K 1 or by a
duly authorized representative of that person. A person is a duly authorized
representative only if:
a. The authorization is made in writing by a person described
in [ Section Part ] III K 1;
b. The authorization specifies either an individual or a position having responsibility for the overall operation of the regulated facility or activity such as the position of plant manager, operator of a well or a well field, superintendent, position of equivalent responsibility, or an individual or position having overall responsibility for environmental matters for the operator. (A duly authorized representative may thus be either a named individual or any individual occupying a named position); and
c. The signed and dated written authorization is included in the SWPPP. A copy must be provided to the department and VSMP authority, if requested.
3. Changes to authorization. If an authorization under [ Section
Part ] III K 2 is no longer accurate because a different individual
or position has responsibility for the overall operation of the construction
activity, a new authorization satisfying the requirements of [ Section
Part ] III K 2 shall be submitted to the VSMP authority as the
administering entity for the board prior to or together with any reports or
information to be signed by an authorized representative.
4. Certification. Any person signing a document under [ Section
Part ] III K 1 or 2 shall make the following certification:
"I certify under penalty of law that I have read and understand this document and that this document and all attachments were prepared in accordance with a system designed to assure that qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations."
L. Duty to comply. The operator shall comply with all
conditions of this [ state general ] permit. Any state
permit noncompliance constitutes a violation of the Virginia Stormwater
Management Act and the Clean Water Act, except that noncompliance with certain
provisions of this [ state general ] permit may
constitute a violation of the Virginia Stormwater Management Act but not the
Clean Water Act. Permit noncompliance is grounds for enforcement action; for
state permit termination, revocation and reissuance, or modification; or denial
of a state permit renewal application.
The operator shall comply with effluent standards or
prohibitions established under § 307(a) of the Clean Water Act for toxic
pollutants within the time provided in the regulations that establish these
standards or prohibitions or standards for sewage sludge use or disposal, even
if this [ state general ] permit has not yet been modified
to incorporate the requirement.
M. Duty to reapply. If the operator wishes to continue an
activity regulated by this [ general ] permit after the
expiration date of this [ state general ] permit, the
operator shall submit a new registration statement at least 90 days before the
expiration date of the existing [ state general ]
permit, unless permission for a later date has been granted by the board. The
board shall not grant permission for registration statements to be submitted
later than the expiration date of the existing [ state general ]
permit.
N. Effect of a state permit. This [ state general ]
permit does not convey any property rights in either real or personal property
or any exclusive privileges, nor does it authorize any injury to private
property or invasion of personal rights, or any infringement of federal, state
or local law or regulations.
O. State law. Nothing in this [ state general ]
permit shall be construed to preclude the institution of any legal action
under, or relieve the operator from any responsibilities, liabilities, or
penalties established pursuant to any other state law or regulation or under
authority preserved by § 510 of the Clean Water Act. Except as provided in
[ state general ] permit conditions on
"bypassing" [ (Section (Part ] III
U) and "upset" [ (Section (Part ] III
V), nothing in this [ state general ] permit shall be
construed to relieve the operator from civil and criminal penalties for
noncompliance.
P. Oil and hazardous substance liability. Nothing in this
[ state general ] permit shall be construed to preclude
the institution of any legal action or relieve the operator from any
responsibilities, liabilities, or penalties to which the operator is or may be
subject under §§ 62.1-44.34:14 through 62.1-44.34:23 of the State Water Control
Law or § 311 of the Clean Water Act.
Q. Proper operation and maintenance. The operator shall at all
times properly operate and maintain all facilities and systems of treatment and
control (and related appurtenances), which are installed or used by the
operator to achieve compliance with the conditions of this [ state general ]
permit. Proper operation and maintenance also includes effective plant
performance, adequate funding, adequate staffing, and adequate laboratory and process
controls, including appropriate quality assurance procedures. This provision
requires the operation of back-up or auxiliary facilities or similar systems,
which are installed by the operator only when the operation is necessary to
achieve compliance with the conditions of this [ state general ]
permit.
R. Disposal of solids or sludges. Solids, sludges or other
pollutants removed in the course of treatment or management of pollutants shall
be disposed of in a manner so as to prevent any pollutant from such materials
from entering state surface waters and in compliance with all
applicable state and federal laws and regulations.
S. Duty to mitigate. The operator shall take all [ reasonable ]
steps to minimize or prevent any discharge in violation of this [ state
general ] permit that has a reasonable likelihood of adversely
affecting human health or the environment.
T. Need to halt or reduce activity not a defense. It shall not
be a defense for an operator in an enforcement action that it would have been
necessary to halt or reduce the permitted activity in order to maintain
compliance with the conditions of this [ state general ]
permit.
U. Bypass.
1. "Bypass," as defined in 9VAC25-870-10, means the
intentional diversion of waste streams from any portion of a treatment
facility. The operator may allow any bypass to occur that does not cause
effluent limitations to be exceeded, but only if it also is for essential
maintenance to ensure efficient operation. These bypasses are not subject to
the provisions of [ Section Part ] III U 2 and 3.
2. Notice.
a. Anticipated bypass. If the operator knows in advance of the need for a bypass, the operator shall submit prior notice to the department, if possible at least 10 days before the date of the bypass.
b. Unanticipated bypass. The operator shall submit notice of
an unanticipated bypass as required in [ Section Part ]
III I.
3. Prohibition of bypass.
a. Except as provided in [ Section Part ]
III U 1, bypass is prohibited, and the board or department may take enforcement
action against an operator for bypass unless:
(1) Bypass was unavoidable to prevent loss of life, personal injury, or severe property damage. Severe property damage means substantial physical damage to property, damage to the treatment facilities that causes them to become inoperable, or substantial and permanent loss of natural resources that can reasonably be expected to occur in the absence of a bypass. Severe property damage does not mean economic loss caused by delays in production;
(2) There were no feasible alternatives to the bypass, such as the use of auxiliary treatment facilities, retention of untreated wastes, or maintenance during normal periods of equipment downtime. This condition is not satisfied if adequate back-up equipment should have been installed in the exercise of reasonable engineering judgment to prevent a bypass that occurred during normal periods of equipment downtime or preventive maintenance; and
(3) The operator submitted notices as required under [ Section
Part ] III U 2.
b. The department may approve an anticipated bypass, after
considering its adverse effects, if the department determines that it will meet
the three conditions listed in [ Section Part ] III U 3
a.
V. Upset.
1. An "upset," as defined in 9VAC25-870-10, means an exceptional incident in which there is unintentional and temporary noncompliance with technology-based state permit effluent limitations because of factors beyond the reasonable control of the operator. An upset does not include noncompliance to the extent caused by operational error, improperly designed treatment facilities, inadequate treatment facilities, lack of preventive maintenance, or careless or improper operation.
2. An upset constitutes an affirmative defense to an action
brought for noncompliance with technology-based state permit effluent
limitations if the requirements of [ Section Part ] III
V 4 are met. A determination made during administrative review of claims that
noncompliance was caused by upset, and before an action for noncompliance, is
not a final administrative action subject to judicial review.
3. An upset does not include noncompliance to the extent caused by operational error, improperly designed treatment facilities, inadequate treatment facilities, lack of preventative maintenance, or careless or improper operation.
4. An operator who wishes to establish the affirmative defense of upset shall demonstrate, through properly signed, contemporaneous operating logs or other relevant evidence that:
a. An upset occurred and that the operator can identify the cause(s) of the upset;
b. The permitted facility was at the time being properly operated;
c. The operator submitted notice of the upset as required in
[ Section Part ] III I; and
d. The operator complied with any remedial measures required
under [ Section Part ] III S.
5. In any enforcement proceeding, the operator seeking to establish the occurrence of an upset has the burden of proof.
W. Inspection and entry. The operator shall allow the department as the board's designee, the VSMP authority, EPA, or an authorized representative of either entity (including an authorized contractor), upon presentation of credentials and other documents as may be required by law to:
1. Enter upon the operator's premises where a regulated
facility or activity is located or conducted, or where records must be kept
under the conditions of this [ state general ] permit;
2. Have access to and copy, at reasonable times, any records
that must be kept under the conditions of this [ state general ]
permit;
3. Inspect and photograph at reasonable times any facilities,
equipment (including monitoring and control equipment), practices, or
operations regulated or required under this [ state general ]
permit; and
4. Sample or monitor at reasonable times, for the purposes of ensuring state permit compliance or as otherwise authorized by the Clean Water Act or the Virginia Stormwater Management Act, any substances or parameters at any location.
For purposes of this section, the time for inspection shall be deemed reasonable during regular business hours, and whenever the facility is discharging. Nothing contained herein shall make an inspection unreasonable during an emergency.
X. State permit actions. State permits may be modified, revoked and reissued, or terminated for cause. The filing of a request by the operator for a state permit modification, revocation and reissuance, or termination, or a notification of planned changes or anticipated noncompliance does not stay any state permit condition.
Y. Transfer of state permits.
1. State permits are not transferable to any person except
after notice to the department. Except as provided in [ Section Part ]
III Y 2, a state permit may be transferred by the operator to a new operator
only if the state permit has been modified or revoked and reissued, or a minor
modification made, to identify the new operator and incorporate such other
requirements as may be necessary under the Virginia Stormwater Management Act
and the Clean Water Act.
2. As an alternative to transfers under [ Section Part ]
III Y 1, this state permit may be automatically transferred to a new operator
if:
a. The current operator notifies the department at least 30 days in advance of the proposed transfer of the title to the facility or property;
b. The notice includes a written agreement between the existing and new operators containing a specific date for transfer of state permit responsibility, coverage, and liability between them; and
c. The department does not notify the existing operator and
the proposed new operator of its intent to modify or revoke and reissue the
state permit. If this notice is not received, the transfer is effective on the
date specified in the agreement mentioned in [ Section Part ]
III Y 2 b.
3. For ongoing construction activity involving a change of operator, the new operator shall accept and maintain the existing SWPPP, or prepare and implement a new SWPPP prior to taking over operations at the site.
Z. Severability. The provisions of this [ state general ]
permit are severable, and if any provision of this [ state general ]
permit or the application of any provision of this state permit to any
circumstance, is held invalid, the application of such provision to other
circumstances and the remainder of this [ state general ]
permit shall not be affected thereby.
9VAC25-880-80. Applicability. (Repealed.)
Operators receiving coverage under this general permit
shall remain subject to the water quality and quantity criteria set forth in
9VAC25-880-82 through 9VAC25-880-90, which specify technical criteria for every
land-disturbing activity regulated by this general permit.
9VAC25-880-82. General. (Repealed.)
A. Determination of flooding and channel erosion impacts to
receiving streams due to land-disturbing activities shall be measured at each
point of discharge from the land disturbance and such determination shall include
any runoff from the balance of the watershed that also contributes to that
point of discharge.
B. The specified design storms shall be defined as either a
24-hour storm using the rainfall distribution recommended by the U.S.
Department of Agriculture's Natural Resources Conservation Service (NRCS) when
using NRCS methods or as the storm of critical duration that produces the
greatest required storage volume at the site when using a design method such as
the Modified Rational Method.
C. For purposes of computing runoff, all pervious lands in
the site shall be assumed prior to development to be in good condition (if the
lands are pastures, lawns, or parks), with good cover (if the lands are woods),
or with conservation treatment (if the lands are cultivated); regardless of
conditions existing at the time of computation.
D. Construction of stormwater management facilities or
modifications to channels shall comply with all applicable laws and
regulations. Evidence of approval of all necessary permits shall be presented.
E. Impounding structures that are not covered by the
Impounding Structure Regulations (4VAC50-20) shall be engineered for structural
integrity during the 100-year storm event.
F. Predevelopment and postdevelopment runoff rates shall be
verified by calculations that are consistent with good engineering practices.
G. Outflows from a stormwater management facility or
stormwater conveyance system, shall be discharged to an adequate channel.
H. Proposed residential, commercial, or industrial
subdivisions shall apply these stormwater management criteria to the land
disturbance as a whole. Individual lots in new subdivisions shall not be
considered separate land-disturbing activities, but rather the entire
subdivision shall be considered a single land development project. Hydrologic
parameters shall reflect the ultimate land disturbance and shall be used in all
engineering calculations.
I. All stormwater management facilities shall have an
inspection and maintenance plan that identifies the owner and the responsible
party for carrying out the inspection and maintenance plan.
J. Construction of stormwater management impoundment
structures within a Federal Emergency Management Agency (FEMA) designated
100-year floodplain shall be avoided to the extent possible. When this is
unavoidable, all stormwater management facility construction shall be in
compliance with all applicable regulations under the National Flood Insurance
Program, 44 CFR Part 59.
K. Natural channel characteristics shall be preserved to
the maximum extent practicable.
L. Land-disturbing activities shall comply with the
Virginia Erosion and Sediment Control Law and attendant regulations.
M. Flood control and stormwater management facilities that
drain or treat water from multiple development projects or from a significant
portion of a watershed may be allowed in Resource Protection Areas defined in
the Chesapeake Bay Preservation Act, provided that (i) the local government has
conclusively established that the location of the facility within the Resource
Protection Area is the optimum location; (ii) the size of the facility is the
minimum necessary to provide necessary flood control, stormwater treatment, or
both; and (iii) the facility must be consistent with a stormwater management
program that has been approved by the board, the Chesapeake Bay Local
Assistance Board prior to its abolishment on July 1, 2012, or the Board of
Conservation and Recreation.
9VAC25-880-84. Water quality. (Repealed.)
A. Compliance with the water quality criteria may be
achieved by applying the performance-based criteria or the technology-based
criteria to either the site or a planning area.
B. Performance-based criteria. For land-disturbing
activities, the calculated postdevelopment nonpoint source pollutant runoff
load shall be compared to the calculated predevelopment load based upon the
average land cover condition or the existing site condition. A BMP shall be
located, designed, and maintained to achieve the target pollutant removal
efficiencies specified in Table 1 of this section to effectively reduce the
pollutant load to the required level based upon the following four applicable
land development situations for which the performance criteria apply:
1. Situation 1 consists of land-disturbing activities where
the existing percent impervious cover is less than or equal to the average land
cover condition and the proposed improvements will create a total percent
impervious cover that is less than the average land cover condition.
Requirement: No reduction in the after disturbance pollutant
discharge is required.
2. Situation 2 consists of land-disturbing activities where
the existing percent impervious cover is less than or equal to the average land
cover condition and the proposed improvements will create a total percent
impervious cover that is greater than the average land cover condition.
Requirement: The pollutant discharge after disturbance shall
not exceed the existing pollutant discharge based on the average land cover
condition.
3. Situation 3 consists of land-disturbing activities where
the existing percent impervious cover is greater than the average land cover
condition.
Requirement: The pollutant discharge after disturbance shall
not exceed (i) the pollutant discharge based on existing conditions less 10% or
(ii) the pollutant discharge based on the average land cover condition,
whichever is greater.
4. Situation 4 consists of land-disturbing activities where
the existing percent impervious cover is served by an existing stormwater
management BMP that addresses water quality.
Requirement: The pollutant discharge after disturbance shall
not exceed the existing pollutant discharge based on the existing percent
impervious cover while served by the existing BMP. The existing BMP shall be
shown to have been designed and constructed in accordance with proper design
standards and specifications, and to be in proper functioning condition.
C. Technology-based criteria. For land-disturbing
activities, the postdeveloped stormwater runoff from the impervious cover shall
be treated by an appropriate BMP as required by the postdeveloped condition
percent impervious cover as specified in Table 1 of this section. The selected
BMP shall be located, designed, and maintained to perform at the target
pollutant removal efficiency specified in Table 1. Design standards and
specifications for the BMPs in Table 1 that meet the required target pollutant
removal efficiency will be available at the department.
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9VAC25-880-86. Stream channel erosion. (Repealed.)
A. Properties and receiving waterways downstream of any
land-disturbing activity shall be protected from erosion and damage due to changes
in runoff rate of flow and hydrologic characteristics, including but not
limited to, changes in volume, velocity, frequency, duration, and peak flow
rate of stormwater runoff in accordance with the minimum design standards set
out in this section.
B. The permit-issuing authority shall require compliance
with subdivision 19 of 9VAC25-840-40 of the Erosion and Sediment Control
Regulations, promulgated pursuant to Article 2.4 (§ 62.1-44.15:51 et seq.)
of Chapter 3.1 of Title 62.1 of the Code of Virginia.
C. The permit-issuing authority may determine that some
watersheds or receiving stream systems require enhanced criteria in order to
address the increased frequency of bankfull flow conditions (top of bank)
brought on by land-disturbing activities. Therefore, in lieu of the reduction
of the two-year post-developed peak rate of runoff as required in subsection B
of this section, the land development project being considered shall provide
24-hour extended detention of the runoff generated by the one-year, 24-hour
duration storm.
D. In addition to subsections B and C of this section,
permit-issuing authorities, by local ordinance may, or the board by state
regulation may, adopt more stringent channel analysis criteria or design
standards to ensure that the natural level of channel erosion, to the maximum
extent practicable, will not increase due to the land-disturbing activities.
These criteria may include, but are not limited to, the following:
1. Criteria and procedures for channel analysis and classification.
2. Procedures for channel data collection.
3. Criteria and procedures for the determination of the
magnitude and frequency of natural sediment transport loads.
4. Criteria for the selection of proposed natural or manmade
channel linings.
9VAC25-880-88. Flooding. (Repealed.)
A. Downstream properties and waterways shall be protected
from damages from localized flooding due to changes in runoff rate of flow and
hydrologic characteristics, including but not limited to, changes in volume, velocity,
frequency, duration, and peak flow rate of stormwater runoff in accordance with
the minimum design standards set out in this section.
B. The 10-year postdeveloped peak rate of runoff from the
development site shall not exceed the 10-year predeveloped peak rate of runoff.
C. In lieu of subsection B of this section, localities may,
by ordinance, adopt alternate design criteria based upon geographic, land use,
topographic, geologic factors or other downstream conveyance factors as
appropriate.
D. Linear development projects shall not be required to
control post-developed stormwater runoff for flooding, except in accordance
with a watershed or regional stormwater management plan.
9VAC25-880-90. Regional (watershed-wide) stormwater
management plans. (Repealed.)
This section enables localities to develop regional
stormwater management plans. State agencies intending to develop large tracts
of land such as campuses or prison compounds are encouraged to develop regional
plans where practical.
The objective of a regional stormwater management plan is
to address the stormwater management concerns in a given watershed with greater
economy and efficiency by installing regional stormwater management facilities
versus individual, site-specific facilities. The result will be fewer
stormwater management facilities to design, build and maintain in the affected
watershed. It is also anticipated that regional stormwater management
facilities will not only help mitigate the impacts of new development, but may
also provide for the remediation of erosion, flooding or water quality problems
caused by existing development within the given watershed.
If developed, a regional plan shall, at a minimum, address
the following:
1. The specific stormwater management issues within the
targeted watersheds.
2. The technical criteria in 9VAC25-880-80 through
9VAC25-880-88 as needed based on subdivision 1 of this section.
3. The implications of any local comprehensive plans, zoning
requirements, local ordinances pursuant to the Chesapeake Bay Preservation Area
Designation and Management Regulations adopted pursuant to the Chesapeake Bay
Preservation Act, and other planning documents.
4. Opportunities for financing a watershed plan through cost
sharing with neighboring agencies or localities, implementation of regional
stormwater utility fees, etc.
5. Maintenance of the selected stormwater management
facilities.
6. Future expansion of the selected stormwater management
facilities in the event that development exceeds the anticipated level.
FORMS (9VAC25-880)
[ Department of Environmental Quality Construction
Activity Operator Permit Fee Form - Form DEQ 199-213 (rev. 08/13)
General Permit for Discharges of Stormwater from Construction
Activities (VAR10) - Notice of Termination - Form DEQ 199-147 (rev. 08/13)
General Permit for Discharges of Stormwater from
Construction Activities (VAR10) - Registration Statement - Form DEQ 199-146
(rev. 08/13)
General Permit for Discharges of Stormwater from
Construction Activities (VAR10) - Transfer Agreement - Form DEQ 199-191 (rev.
08/13)
Department of Environmental Quality Construction Activity Operator Permit Fee Form (rev. 01/2014)